background image

TFT COLORFUL DISPLAY

MULTIPLE-CHANNEL WEATHER STATION

Operation Manual

Содержание HP3000

Страница 1: ...TFT COLORFUL DISPLAY MULTIPLE CHANNEL WEATHER STATION Operation Manual ...

Страница 2: ...OVERVIEW 1 Inventory of contents 1 Base station 2 Five thermo hygrometers 4 Power adapter 5 User manual Console Figure 1 Figure 2 Outdoor sensors Figure 3 2 Introduction ...

Страница 3: ...t Up Note To avoid operating problems please take note of battery polarity before when inserting any Alkaline Batteries permanent damaged could be introduced by inserting the battery in wrong direction Do not use rechargeable batteries We recommend fresh alkaline batteries for outdoor temperature range between 20 and 60 and fresh lithium batteries for outdoor temperature range between 40 and 60 1 ...

Страница 4: ...in Figure 6 Figure 6 1 Temperature 2 Temperature units or 3 Channel number 4 Relative humidity 7 Repeat for the additional remote sensor verifying each remote is on a different channel 3 2 Display Console Set Up 1 Move the sensors about 1 3 meters away from the display console With multiple sensor make sure all sensors are powered up 2 Power on the display console by connecting the power adapter T...

Страница 5: ...lly captured The regular RF link will resume once RCC reception routine is finished In some locations RCC reception may take a couple of days to receive the signal Once the radio controlled time is RCC reception icon will turn on reference Figure 9 4 Remote Sensor Installation z Before mount the units ensuring that the receiver can still pick up the signal from transmitters It is recommended to mo...

Страница 6: ... area in turn 5 Outdoor Temperature Dew point heat index humidity for channel 3 and other channels defined to be displayed in CH3 area in turn 6 Outdoor Temperature Dew point heat index humidity for channel 4 and other channels defined to be displayed in CH4 area in turn 7 Outdoor Temperature Dew point heat index humidity for channel 5 and other channels defined to be displayed in CH4 area in turn...

Страница 7: ...to increase the brightness Brightness control key Press this key to decrease the brightness Menu Key Press this key to enter menu and scroll to different modes 5 2 Setup Mode Under Normal mode press MENU key once to enter Setup Mode Icon Description Scroll right key Press this key to scroll down right Selection key Press this key to select and enter the option ...

Страница 8: ... to scroll down up Selection key Press this key to select and enter the option Scroll left key Press this key to scroll right left Return key Press this key to back to Setup main menu Press and key a red dot will be moving among these boxes Each box represents a certain channel 1 8 and parameter Temperature dew point heat index Press key the wanted parameter of wanted channel would be displayed on...

Страница 9: ...lly once you select the channel Graph Time This is to set length of history time for graph among 12h 24h 48h 72h Time Format Select time format between AM h mm ss h mm ss AM h mm ss Date Format Select date format between MM DD YYYY and DD MM YYYY Date and time This is to set time date DST and time zone Temperature Units This is to select temperature units between and 5 3 Calibration Mode Under Nor...

Страница 10: ......

Страница 11: ...ume key Press this key to cancel the calibration and resume the data Scroll up left key Press this key to scroll up left Mode key Press this key to enter to next mode Return Key Back to main menu of calibration mode 5 4 Max Min Alarm Mode Under Normal mode press MENU key three times to enter Max Min Alarm Mode Users can check max min records of temperature humidity dew point heat index of each sen...

Страница 12: ...eter to check according max min records Switch on off alarms and increase the value during alarm setup Value Decrease key Decrease the value during alarm setup Scroll up left key Press this key to scroll up left Mode key Press this key to enter to next mode Return Key Back to main menu of calibration mode Temperature Max Min interface ...

Страница 13: ...Humidity Max Min interface Dew point Max Min interface ...

Страница 14: ...umidity setting To enter alarm setting interface you need to select the alarm ON default OFF scroll to OFF key before Humidity alarm and press key to switch on the alarm Then scroll to Humidity alarm and press key to enter humidity alarm setting mode ...

Страница 15: ...sound and flash for 120 seconds the alarm icon will turn to red color high alarm or blue color low alarm The alarm icon will show on display console until the weather condition doesn t meet the user set level Press any key to mute the alarm color change as below color ...

Страница 16: ...red Beep alarm stop grey High Low alarm of Temperature setting To enter alarm setting interface you need to select the alarm ON default OFF scroll to OFF key before Temperature alarm and press key to switch on the alarm Then scroll to Temperature alarm and press key to enter Temperature alarm setting mode ...

Страница 17: ...m The alarm icon will show on display console until the weather condition doesn t meet the user set level Press any key to mute the alarm color change as below color High alarm Red grey red Low alarm Blue grey blue High alarm Low alarm both activated Red grey blue grey red Beep alarm stop grey 5 5 Factory Under Normal mode press MENU key four times to enter factory mode ...

Страница 18: ... device to factory initial settings Clear Max Min Clear Max Min records of specified outdoor sensor Re register sensor If the sensor display please scroll to it and enter to Re register the sensor About Check version information ...

Страница 19: ...ish To switch language Backlight Set the automatically on off time spot of back light And adjust the brightness range 6 Specification Transmission distance in open field 100meter max Frequency 868MHz 915MHz ...

Страница 20: ...oor sensor channel 1 61s Outdoor sensor channel 2 62s Outdoor sensor channel 3 63s Outdoor sensor channel 4 69s Outdoor sensor channel 5 65s Outdoor sensor channel 6 66s Outdoor sensor channel 7 67s Outdoor sensor channel 8 68s Power consumption Base station 5V DC adaptor included Indoor sensor 2xAA alkaline batteries not included Remote sensor 2xAA rechargeable batteries not included ...