background image

 

 

 

 

PROTECTION AGAINST SOLIDS AND WATER 

 

Only for IP-rated fixtures 

The protection level of a housing is set by applied standards. For classification there is used the IP-Code. 

It contains the declaration „IP“and two following numbers. The first number characterizes the protection 

against harmful effects of solids, the second is rating the water protection. It is important to distinguish 

whether encapsulation and harmful effect! There can be housing that is not capsuled completely but still 

avoids harmful effect of solids or water. 

PROTECTION EXAMPLES: 

IP20:

  Protection against intruding objects >12,5mm „Finger protected “; No waterproofing. 

TYPICAL 

PROTECTION FOR INDOOR USE FIXTURES 

IP33

: Protection against intruding objects >2,5mm; Falling water within an angle of 60° has no harmful 

effect 

TYPICAL PROTECTION OF LED-LIGHTS USING RECESSED POWERCON AND DMX SOCKET

. This 

protection is linked to the mounting position of the fixture and always refers to typical mounting situation 

like a Floor spot used standing on the ground. 

IP54

: complete protection against solids and low-pressure water from any side 

THIS TYPE OF FIXTURES 

CAN BE USED UNDER NORMAL OUTDOOR CONDITIONS

IP65

: shielded against dust and pressurized water from any side. 

TYPICAL PROTECTION FOR OUTDOOR 

RATED EVENTFIXTURES USING WATERPROOFED POWER AND SIGNAL LINK. 

IP67

: shielded against dust and protected for accidental  briefly submerge. 

PROTECTION AGAINST 

ACCIDENTIAL SUBMERGING ON TEMPORARY FLOODED AREA. 
 

TEMPORARY USE 

 

Event equipment is designed for temporary use. This are typical purpose as concerts, festivals, theatre, 

clubs and disco use and referable venues. Long-term use, specially under outdoor conditions and fixed 

outdoor installation can bring damage in aging materials and affect the coated surface. Sealings as well as 

cables are made from rubber material and will age by long-term UV-emission as sunlight and should be 

checked frequently. 

 

LIMITATIONS OF IP PROTECTION 

 

Содержание FOS PAR 7x15 6 in 1

Страница 1: ...1 FOS PAR 7x15 6 in 1 ...

Страница 2: ...ARNING This product must be installed by a qualified professional All maintenance must be carried out by a qualified electrician A minimum distance of 0 5 m must be maintained between the equipment and a combustible surface The product must always be operated in a well ventilated area DO NOT stare directly into the light source Always disconnect the power before carrying out any maintenance The ea...

Страница 3: ...tection is linked to the mounting position of the fixture and always refers to typical mounting situation like a Floor spot used standing on the ground IP54 complete protection against solids and low pressure water from any side THIS TYPE OF FIXTURES CAN BE USED UNDER NORMAL OUTDOOR CONDITIONS IP65 shielded against dust and pressurized water from any side TYPICAL PROTECTION FOR OUTDOOR RATED EVENT...

Страница 4: ...t or sitting position using the supporting brackets NOTE The LED MODULE can be mounted at any angle and in any position It is possible to further adjust the angle of the LED MODULE using the two adjustment knobs located on the side of the fixture NOTE If the signal cable is over 60 m between the DMX512 controller and fixture or between two fixtures then a DMX signal amplifier is needed as well Men...

Страница 5: ...DE99 Color fade CP99 Color pulse SU01 Sound Active color change Channel Modes 6 Channels 1 Red 0 255 Red Color Linear Dimming 2 Green 0 255 Green Color Linear Dimming 3 Blue 0 255 Blue Color Linear Dimming 4 White 0 255 White Color Linear Dimming 5 Amber 0 255 Amber Color Linear Dimming 6 Ultra Violet 0 255 UV Color Linear Dimming 10 Channels 1 Master Dimmer 0 255 Dimming to all the colors 2 Red ...

Страница 6: ...ade Adjustable Speed with channel 10 201 250 Auto Color Pulses Adjustable Speed with channel 10 251 255 No Function 10 Speed 0 255 Macro Color Speed from slow to fast in combination with Channel 9 General Information Replacing a fuse Always disconnect the fixture from main power before replacing a fuse Use only the appropriate fuse with the same type and rating A fuse with different rating can dam...

Отзывы: