FOS Technologies Beam 230W Hybrid Скачать руководство пользователя страница 4

 

4/8                                                                                                                             

                                                                               

    ATTENTION

 

                                                                          RISK OF SHORT CIRCUIT

 

                                                                               

    ATTENTION

 

                                                                          RISK OF SHORT CIRCUIT

 

                                                                               

    ATTENTION

 

                                                                      DANGER OF LIFE

RISKOF FIRE

 

                                                                          RISK OF SHORT CIRCUIT

 

a  warm  environment  it  must  only  be  taken  into  operation  once  it  has  reached  ambient  temperature,since  the 
condensation created by the difference in temperature may destroy the device! 
 
Protect the product against dust!Dust may reduce the protective insulation,which may cause fatal electric shocks! 
 
The product must be operated at altitudes ranging between 20m below and 3000m above sea level only! 
 
The product must not be operated during thunder storms;risk of destruction from surge voltages! 
 
The product must be operated at a minimum distance of 1.5m to lit objects only! 
 

5.    Installation 

 

 

 

 

This product can be operated suspended or as stand-alone system. 
 
Should your lighting effect show any signs of damage,do not install the device!In this case,have your lighting effect 
repaired  by  your  specialized  dealer.The  manufacturer  does  not  accept  responsibility  or  liability  for  damage  to 
property or personal injury resulting from an improperly installation! 
 
As  a  stand-alone  system  the  device  must  be  installed  vertically  on  an  absolute  planar,firm,fireproof,shock  and 
vibration-free surface.The installation of this lighting effect must be carried out by trained and professional staff!The 
installation of this lighting must only be carried out with the appropriate materials! 
 
The suspended installation of this lighting effect necessitates a suitable suspension system!The lighting effect must 
never  be  fixed  swinging  freely  in  the  room.No  individuals  should  linger  underneath  the  lighting  effect  during 
suspended installation! 
 
It is a must to install this device with a second independent fixture.Such second fixture must guarantee in the event 
of failure of the main fixture that no assembly parts will fall down.Use the fixture on the undersurface only. 
 
The light effect unit must be attached via two certified hooks and omega bracket to a tie-bar system.Use the screw 
threads on the undersurface only. 
 
It  must  be  ensured  that  an  expert  inspects  the  mechanical  and  safety-relevant  installation  prior  to  the  initial 
operation  and  following  major  modifications,prior  to  the  renewed  operation.It  must  be  ensured  that  an  expert 
inspects  the  mechanical  and  safety-relevant  installation  at  least  once  a  year.It  must  be  ensured  that  an  expert 
inspects  the  mechanical  installation  and  the  installation  of  relevance  to  safety  within  the  framework  of  an 
acceptance test at least every four years. 
 
The installation fixture must be as such that it can withstand for a period of 60minutes 10 times the load capacity 
without harmful deformation. 
 
It is prohibited for any individual to unnecessarily stay or pass beneath the installation during any type of assembly 
work 

The light effect unit must be secured by a safety arrester cable if fly-mounted.The cable must withstand 12 times the 
weigh of the light effect unit Use arrester cables equipped with quick closing links.The dropping distance must not 
exceed 20 cm.Defect arrester cables or arrester cables that have already been exposed to stress must not be used. 

 

6.  Operation

 

 

 

 

 

Controls 

 

 

Link all DMX devices with a DMX-512 controller by using a standard,3-pin DMX cable.Connect the output of the first 
device with the input of the second device and the output of the second device with the input of the third device and 
so on. 
 
Connect the mains plug to an outlet. 
 
Operating the product for the first time may generate smoke and odour,this is not a defect.Avoid dis/connecting the 
product repeatedly and quickly from/with mains!Always wait 15 minutes prior to the next dis/connection! 
 
The  device  starts  not  until  a  self-testing  and  starting  time.If  the  moving  head  is  ready  to  start,push  and  roll  the 
function wheel.The LCD display shows the options,as below: 

 
7.  Lamps 

 

 

Содержание Beam 230W Hybrid

Страница 1: ...1 8 Beam 230W Hybrid USER MANUAL Congratulations on purchasing this 230W moving Beam Light Thank you for extending your trust in our technology...

Страница 2: ...ting instructions to warrant this condition and the safe operation of hte product Any damage caused as a result of the non compliance with these operating instructions leads to the expiration of any w...

Страница 3: ...the mains cord mains plug and outlet with wet or damp hands When not using the product and proform to cleaning always disconnect the product from mains To do so hold the mains plug by the handling su...

Страница 4: ...ly parts will fall down Use the fixture on the undersurface only The light effect unit must be attached via two certified hooks and omega bracket to a tie bar system Use the screw threads on the under...

Страница 5: ...he fuse holder cover with an appropriate screwdriver Remove the old fuse and place the fuse inside the holder Replace the fuse holder and insert it Never connect the lighting effect to the mains prior...

Страница 6: ...value can not be changed only show channel DMX value While there is no DMX controllers you can control the fixture by this item select some channel roll the encoder wheel to adjust DMX value 09 Displ...

Страница 7: ...N GREEN GREEN LIGHT GREEN LIGHT GREEN LIGHT GREEN LAVENDER LAVENDER LAVENDER PINK PINK PINK YELLOW YELLOW YELLOW MAGENTA MAGENTA MAGENTA CYAN CYAN CYAN CTO 260 CTO 260 CTO260 CTO 190 CTO 190 CTO 190 C...

Страница 8: ...hake slow to quick Gobo15 Shake slow to quick Gobo16 Shake slow to quick 5 Prism 0 127 128 255 No prism Prism 6 Prism rotation 0 21 42 63 84 105 127 128 190 191 192 193 255 0 90 180 270 360 450 540 Pr...

Отзывы: