Table of contents

1. Introduction

1-1. Transportation
1-2. Preliminary steps
1-3. Initial setup 
1-4. Important safety instructions
1-5. Maintenance, service and faults

2. Operation

2.1 Unpacking and inspection
2.2 UPS front and rear panel views
2.3 Installation procedure
2.4 UPS connections
2.5 Turning on the UPS
2.6 Battery replacement
2.7 ForzaTracker monitoring software

3. Advanced operation

3.1 Button and function description
3.2 LCD panel
3.3 Audible alarm
3.4 Abbreviations on the LCD display
3.5 UPS parameter settings
3.6 Operation mode description
3.7 Fault codes
3.8 Warning indicators

4. Troubleshooting
5. Storage and maintenance
6. Technical specifications

1. Introduction

Thank you for purchasing the Forza FDC-1502R and FDC -3002R Online UPS. To enjoy all the features and benefits of this unit, please 
read and follow all installation and operation instructions thoroughly before unpacking, installing or operating this device. After you 
have read this manual, keep it in a safe place for future reference.
The information contained in this manual covers the 1500VA and 3000VA uninterruptible power system, its basic functions, operating 
procedures, options available and troubleshooting guide. It also includes information on how to ship, store, handle, and install the 
equipment.

1-1. Transportation

• Make sure to transport the UPS system only in the original package to protect it against shock and impact.

1-2. Preliminary steps

 • Water condensation may occur if the UPS is unpacked in a very cold environment and then moved to a warmer location. 
 • The UPS must be thoroughly dry before being installed. Failure to do so may increase the risk of electric shock. 
 • Do not install the UPS system near water or in moist environments. 
 • Do not install the UPS system where it would be exposed to direct sunlight or near a heater or heating vent. 
 • Do not block ventilation holes in the UPS housing.

1-3. Initial setup

Do not connect appliances or equipment that may overload the UPS system (such as a laser printer) to the output sockets. 
Place cables in such a way that no one can step on or trip over them. 
Do not connect domestic appliances, such as hair dryers, to the UPS output sockets. 
Connect the UPS system only to an earthed shockproof outlet which must be easily accessible and close to the UPS system.
Use only CE-marked mains cable (e.g. the mains cable of your computer) to connect the UPS system to the
building wiring outlet (shockproof outlet).
Use only CE-marked power cables to connect the loads to the UPS system. 
During the installation of this equipment, make sure that the sum of the leakage currents of the UPS and the connected loads shall 
not exceed 3.5 mA.

CAUTION:

 The unit is heavy. Lifting the unit requires a minimum of two people.






1-4. Important safety instructions

Do not disconnect the mains cable on the UPS system or the building wiring outlet (shockproof socket outlet) at any time, since this 
would cancel the protective earth of the UPS system and of all connected loads. 
Connect the UPS only to a grounded socket that meets electrical safety guidelines. 
Locate the UPS near a wall socket. Do not use an extension cord between the UPS and the socket. 
In the event of an emergency, press the OFF/Enter button and disconnect the power cord from the AC mains to properly disable 
the UPS. 
Do not allow any kind of liquid or foreign object to enter this UPS unit. Do not place beverages or any other containers with liquid 
on or nearby the unit.
The UPS can be operated by any individual with no previous experience.



Содержание FDC-1502R

Страница 1: ...2 Y e a r w a r r a n t y...

Страница 2: ...k Do not install the UPS system near water or in moist environments Do not install the UPS system where it would be exposed to direct sunlight or near a heater or heating vent Do not block ventilation...

Страница 3: ...y can result in electrical shock The likelihood of such shock can be reduced if such grounds are removed during installation and maintenance When replacing the battery make sure to use the same type a...

Страница 4: ...S it will provide advanced communication and monitoring options Note The USB port and RS 232 port cannot be used at the same time CAUTION For 1 5K model to reduce the risk of re connect only to a circ...

Страница 5: ...n the same LAN no matter how far they might be from the UPS 2 6 Battery replacement Service personnel only NOTICE This UPS is equipped with internal batteries and only quali ed service personnel shall...

Страница 6: ...r display Load information UPS status Battery information Display Function Backup time information Overload indicator Indicates the load or the UPS output is short circuited Indicates that the program...

Страница 7: ...Two parameters need to be configured in order to set up the UPS Refer to following diagram Parameter 1 it is used for the different configuration options Please refer to the table below Parameter 2 it...

Страница 8: ...3 is from 7V to 24V of the nominal voltage Default 12V For 100 110 115 120 127 VAC models the setting voltage in parameter 3 is from 3V to 12V of the nominal voltage Default 6V 08 Bypass voltage range...

Страница 9: ...tting Parameter 3 Sets the backup time limits for the programmable outlets 0 999 Use this setting to define the programmable outlets backup time in minutes from 0 999 in order to connect non critical...

Страница 10: ...t voltage is within the voltage regulation range 3 V max the UPS will bypass voltage to loads for energy saving PFC and INVERTER are disabled in this mode When input frequency is between 40Hz and 70Hz...

Страница 11: ...s connected to the UPS outlet The AC input cable is not properly connected Line and neutral conductors of UPS input are reversed The external or internal battery connection is incorrect Battery voltag...

Страница 12: ...S system contains no user serviceable parts If the battery service life 3 5 years at 25 C ambient temperature has been exceeded the batteries must be replaced In this case please contact your dealer o...