CSD 

Relate Command 

Modem Initial Command 

AT&F0<cr>  // restore parameters 
AT+IPR=115200<cr> 

// setting fixed baud rate 

AT&W<cr>  //

保存参数

 

Note: 
n=0/300/600/1200/2400/4800/9600/14400/28800/38400/57600/115200

M12S211 factory defautl baud rate is 0(auto detect), other types 

factory default baud rate is 115200

 

Server Initial 

ATS0=2<cr> // auto answer after 2 ring received. 
 

Client Dial A Data Call 

ATD[dn]<cr> 

// data call without “;”, and [dn] is the CSD server number 

 

Server Manual Answer 

ATA<cr> 

// manual answer 

 

Comunication Operate Command 

+++ 

// terminal data transfer, back to the command mode 

ATO<cr> 

// switch command mode to data transfer mode 

 

 

 

Hang Up 

ATH<cr> 

// hang up the data channel 

Содержание M1 series

Страница 1: ...User Manual M1 Series Wireless Modem 2 24 2010 Forwell Wireless Co Ltd Shandy Feng...

Страница 2: ...User Manual Type text Page 2 M1 Series Wireless Modem User Manual Power by Forwell Wireless...

Страница 3: ...Wireless device MUST BE POWERED OFF The Forwell Wireless device can transmit signals that could interfere with this equipment Do not operate the Forwell Wireless device in any aircraft whether the air...

Страница 4: ...Forwell Wireless product regardless of the number of events occurrences or claims giving rise to liability be in excess of the price paid by the purchaser for the Forwell Wireless product Copyright 20...

Страница 5: ...Interface Specification Connection Login the router Configuration Describe 3G Router Operation Mode Internet settings Wide Area Network WAN Settings Local Area Network LAN Settings DHCP Client List S...

Страница 6: ...User Manual Type text Page 6 System Management Upgrade Firmware Settings Management Access Point Status Statistic System Log Product Parts List...

Страница 7: ...time of release Document History Version Comments Date Writer 1 00 Standard 2008 7 7 Yuhui 1 10 Fix some bugs 2009 5 3 Gavin 2 00 Modify the document structure Add product type Add function descriptio...

Страница 8: ...SMA Small Adapter SMS Short Message Services Produclist M11 M11S111 GSM 900 1800 RS 232 DB9 M12 M12S211 GPRS 900 1800 RS 232 DB9 M12Z111 GPRS 850 900 1800 1900 RS 232 DB9 M12AZ1411 GPRS 850 900 1800...

Страница 9: ...h compatible with EMC and will be your best choose of wireless communication Features AT command interface Support GSM GPRS CDMA2000 1X Support Voice SMS and CSD Dial up data communication except M11...

Страница 10: ...e 2 2 GPRS EGSM 900 Mhz Class 4 2W DCS 1800 Mhz Class 1 1W PCS 1900 Mhz Class 1 1W M12N111 GSM phase 2 2 GPRS EGSM 900 Mhz Class 4 2W DCS 1800 Mhz Class 1 1W M12N211 GSM phase 2 2 GPRS EGSM 900 Mhz Cl...

Страница 11: ...sale terminals Traffic signals monitor and control Fleet management Power distribution network supervision Central heating system supervision Weather station data transmission Hydrologic data acquisi...

Страница 12: ...12AZ1411 AND M12AC111 is different form above as shown in the diagram below LED Serial OFF No serial data communication FLASH serial data communication Ring OFF NO call ON Telephone ringing Data ON De...

Страница 13: ...nual Type text Page 13 Assemble the antenna connect to PC via RS 232 power on Open the Hyperterminal Windows start menu all programs Accessories Communications Hyper Terminal Enter the name of the con...

Страница 14: ...User Manual Type text Page 14 Choose the communication port Setting the port properties Note the ForwellWireless Modem port properties factory default is 115200 8 n 1 0 as above picture...

Страница 15: ...User Manual Type text Page 15 If the port parameters is different to your setting click disconnect then click properties Click the Configure Port parameters Propertie Disconnect Call...

Страница 16: ...User Manual Type text Page 16 Comfirm the parameters again After setting the Hyper Terminal window as above Click call buttom the Hyper Terminal is ready for operate Port parameters...

Страница 17: ...se sensitive prefix by at and terminate by cr Commonest Command AT CSQ cr signal query AT IPR cr query device baud rate AT IPR 115200 cr baud rate setting support 115200 57600 38400 19200 9600 4800 24...

Страница 18: ...number Hello Forwell message by ASCII sets terminate character means Ctrl Z 0X1A CMGS nnn message stamp OK Note if no message stamp return please resend the message again M11 M12 Message Relate Comman...

Страница 19: ...here is the AT CNMA must sent after received the new SMS M12Z1411 M12AZ1411 M12Z1511 M12AZ1511 SMS M12Z1411 M12AZ1411 M12Z1511 M12AZ1511 Query SMS Center AT CSCA cr query the SMS center number which a...

Страница 20: ...MT MT cr Preferred SMS message storage AT CSMS 1 cr Select Message Service CSMS 1 1 1 OK AT CNMI 1 1 cr New SMS message indications setting OK CMTI MT 1 New SMS message indications AT CMGR 1 cr read...

Страница 21: ...Command AT CMGL ALL cr list SMS AT CMGR n cr read SMS location value is n AT CMGD n cr delete SMS location value is n M13Z311 M13Z811 Receive SMS at cnmi 2 1 1 1 0 setting new SMS notification OK ZCA...

Страница 22: ...number 13691978232 SMS content length 11 acknowledge ASCII priority interactive encryption restricted Hello world ctrl z SMS content and terminal charactor OK HSMSSD OK acknowledge M13H211 M13H311 Com...

Страница 23: ...User Manual Type text Page 23 HMTI MT n m SMS acknowledge normal SMS location n storage media m HDSI SR n m SMS acknowledge statu report location n storage media m...

Страница 24: ...text Page 24 Dial Up Follow is the dial up instance use the Windows XP environment Note M11S111 GSM Modem do not support the dial up function Phone and Modem Option My Computer Control Panel Phone an...

Страница 25: ...User Manual Type text Page 25 Modem tab Add Select Don t detect my modem I will select it from a list...

Страница 26: ...User Manual Type text Page 26 Select Standard 19200 bps Modem Select port COM1...

Страница 27: ...User Manual Type text Page 27 Finish Setting the 19200 Modem Open the standard 19200 bps Modem properies...

Страница 28: ...User Manual Type text Page 28 Tab Modem change the maximun port speed to 115200 Open tab Diagnostics Query Modem for detect the modem statu...

Страница 29: ...Advanced fill the extra initialization commands Type Extra initialization command M12S211 AT CGDCONT 1 IP CMNET M12Z111 AT CGDCONT 1 IP CMNET M12AZ1411 M12AC111 M12O111 M12N111 M12N211 M12G111 M12H111...

Страница 30: ...M12S211 M12Z111 M12O111 M12N111 M12N 211 M12G111 M12H111 M13...

Страница 31: ...Add Connection Open the Network Connections...

Страница 32: ...User Manual Type text Page 32 Create a new connection Click next...

Страница 33: ...User Manual Type text Page 33 Choose commect to the internet Set up my connection manually...

Страница 34: ...User Manual Type text Page 34 Connect using a dial up modem Type the name of connection...

Страница 35: ...M12 M13 Input the ISP phone number 99 1 for M12 and 777 for M13 Select the account M12 M13 Type the ISP account name and password wap wap for M12 in the China Mobile and...

Страница 36: ...User Manual Type text Page 36 card card for M13 in the China Telecom Finish M12 M13 Open the dial up connection click properties...

Страница 37: ...M12 M13 Click configure Chang the maximun speed to 115200 Dial Up...

Страница 38: ...N Setting APN Setting The APN is special parameter provide by ISP Follow is a sample by China Mobile which APN is CMNET AT CGDCONT 1 IP CMNET M12S211 AT CGDCONT 1 IP CMNET M12Z111 M12O111 M12N111 M12N...

Страница 39: ...VPDN Setting The VPDN have special user name and password whick provice by the ISP The follow sample is the provide by China Telecom...

Страница 40: ...efautl baud rate is 0 auto detect other types factory default baud rate is 115200 Server Initial ATS0 2 cr auto answer after 2 ring received Client Dial A Data Call ATD dn cr data call without and dn...

Страница 41: ...Open Shortcut 30 mins Shortcut Open 5 mins Shortcut Shortcut K3 Describe RG Shortcut Reserve GT Shortcut Monitor receive Empty Reserve NOTICE M12AZ1411 does not have Hardware flow monitoring M12AC111...

Страница 42: ...User Manual Type text Page 42 K1 K2 K3 K4 R G T A B C The settings of K1 K2 and K3 is same to the table above it increase K4 setting method is below K4 Normal working AB shortcut Upgrade BC shortcut...

Страница 43: ...Name Input Output PIN Describe Memo Red EPP O Output Positive Vout 3 7V Green EPN O Output Negative Yellow MICP I Input Positive Vimax 1 03Vpp at Ri 2 Vsupply 2 65V at Rsupply 4K Black MICN I Input N...

Страница 44: ...oduct List Name Unit Quantity Describe Picture M1 Item 1 Device Garantee Card Piece 1 Standard Supply Power Adapter Item 1 DC 9V1A RS 232 Cable Item 1 Standard Supply Antenna Item 1 Standard Supply Pr...

Отзывы: