The following events may occur during normal operation.
1.  

Compressor protection

         The compressor cannot restart for 3-4 minutes after it stops.

2.  

Defrosting 

         Frost may be generated on the outdoor unit during heat cycle  when the outdoor temperature is 
         low and the humidity is high resulting in lower heating  efficiency of the air conditioner. 
         During this condition air conditioner will stop heating operation and start  defrosting automatically.
         The time to defrost may vary from approximately 4 to 10 minutes  according to the outdoor 
         temperature and  the amount of frost built up on the  outdoor unit.

3.  

White mist coming out from the indoor unit

         White mist may come out due to a large temperature difference between  the air inlet and air 
         outlet on COOL mode in an indoor environment that has a high  relative humidity.
         White mist may come out due to moisture generated from defrosting  process  when the  air 
         conditioner restarts in HEAT mode operation after defrosting.

4. 

Low noise of the air conditioner

         You may hear a low hissing sound when the compressor is running or has just  stopped running. 
         It is the sound of the refrigerant flowing or coming to  stop.
         You can also hear a low "squeak" sound when the compressor is running or has just stopped 
         running. This is caused by heat expansion and cold contraction of the  plastic parts in the unit 
         when the temperature is changing.
         A noise may happen due to louver restoring to its original position when the power is turned on.

5.  

Dust is blown out from the indoor unit.

      This is a normal condition when the air conditioner has not been  used for a prolonged period or 
       during first use of the unit.

6.  

A peculiar smell comes out from the indoor unit.

      This is caused by the indoor unit giving off smells permeated from building  material, furniture, 
      or smoke. 

7.  

The air conditioner turns to FAN mode from COOL or HEAT  mode.

      When indoor temperature reaches the temperature setting on the air conditioner, the  compressor will 
      stop automatically, and the air conditioner will turn to FAN mode.  The compressor will start again 
      when the indoor temperature rises on COOL mode or falls on HEAT mode to the set point.

9. 

Water leakage

    Water leakage may generate on the surface of the indoor unit when cooling in a high 
    relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to
    the maximum air outlet position and select HIGH fan speed.

10. 

Heat mode 

    The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit
    during heating operation. When the outdoor temperature falls, heat drawn in by the air 
    conditioner will decrease accordingly. At the same time, heat loading of the air conditioner 
    will increase due to larger difference between indoor and outdoor temperature. If a 
    comfortable temperature can't be achieved by the air conditioner, we suggest you use a 
    supplementary heating device.

11. 

Auto-restart function 

     Power failure during operation will stop the unit completely.
     When the power restores, the unit will restart automatically with all the previous settings preserved 
     by the memory function.

8.  

The air conditioner runs 

function after turning off the unit.

     

When turning off the unit under COOL and DRY mode, the air conditioner will run 

 

     function for 7-10 minutes. 

then the operation will be stopped and the unit will turn off automatically. 

Anti-mildew

 

Anti-mildew

 

     If turning off the unit when HEAT mode, the unit will continue operating for about 30 seconds 
     at LOW fan speed, 

11

11

12

12

TROUBLE SHOOTING

Содержание FSAV10M14

Страница 1: ...Before operating the unit please read this manual thoroughly and retain it for future reference Model FSAV10M14 FSAV13M14 FSAV19M14 DC Inverter Split Air Conditioner User Manual...

Страница 2: ...cord length or share the outlet with other appliances Ensure earthed effectively Disconnect the main power if strange sounds smell or smoke comes from the unit Close the door while the air conditioner...

Страница 3: ...hing around air inlets or inside the air outlet Do not use strong deter gent such as thinner but use a soft cloth If bracket is damaged it may cause damage due to falling of unit It may cause fire or...

Страница 4: ...e into operation and cause the unit to function abnormally 2 If the air conditioner runs for a long time in cooling mode and the humidity is high condensed water may drip out ofthe unit Please sets th...

Страница 5: ...ot move the horizontal louver manually Otherwise the horizontal louver will be out of sync Please cease operating unplug the power for a few seconds and restart the air conditioner Do not operate the...

Страница 6: ...ntrol 3 The outdoor unit requires periodic maintenance and cleaning Do not attempt to do this yourself Contact your dealer or service provider Check if the wiring is broken off or disconnected Check i...

Страница 7: ...liar smell comes out from the indoor unit This is caused by the indoor unit giving off smells permeated from building material furniture or smoke 7 The air conditioner turns to FAN mode from COOL or H...

Страница 8: ...proper testing or unauthorized repair B to cosmetic problems or defects which result from normal wear and tear under ordinary use yet not affecting the performance or use of the product C if the produ...

Отзывы: