MAINTENANCE AND TECHNICAL HINTS 

FIG. 07

To  replace  only  the  handle  (7.A)  follow  the 

instructions given below:

Remove the CAP (7.C), loosen the grub screw 

(7.B) and pull out the handle (7.A).

Install the new handle (7.A) and fasten it using 

the grub screw (7.B), complete by inserting the 

cap (7.C).

To  replace  only  the  handle  (7.M)  follow  the 

instructions given below:

Pull out the cap (7.L), loosen the grub screw (7.I) 

and remove the handle (7.M).

DO  NOT  move  the  bar  of  the  new  cartridge 

(7.Q) so as to not compromise the calibration.

Reassemble  the  new  handle  (7.M)  and  lock 

it  with  the  grub  screw  (7.I).  Complete  the 

installation by inserting the cap (7.L).

To replace the cartridge (7.V), remove the cap 

(7.C), loosen the grub screw (7.B) and pull out 

the handle (7.A). After disassembling the plate 

(7.H) screw on the stop cocks (7.S) in clockwise 

direction using a screwdriver. Remove the screw 

(7.D) and the joint (7.E). 

Using  a  wrench,  remove  the  lock  nut  (7.U), 

pull  out  the  cartridge  (7.V)  and  replace  it  if 

necessary. Carefully clean the support sealing 

surfaces  of  the  gaskets  and  reassemble  in 

reverse order. Tighten the lock nut (7.U) so as to 

ensure a proper sealing and enable a smooth 

operation of the handle (7.A).

To  replace  the  thermostatic  cartridge  (7.Q), 

remove the cap (7.C), loosen the grub screw 

(7.B) and pull out the handle (7.A). After sliding 

off the plate (7.H) screw on the stop cocks (7.S) 

in clockwise direction using a screwdriver. 

To  replace  the  thermostatic  cartridge  with  the 

handle (7.T) follow the instructions given below:

remove  the  grub  screw  (7.R)  and  pull  out  the 

thermostatic cartridge with the handle (7.T). Fit 

the new assembly (7.T) into the faucet housing 

carefully aligning the positioning hole with the 

grub  screw  housing  (7.R).  Tighten  the  grub 

screw  without    forcing  it  so  as  to  not  cause 

malfunctionings or damages.

To replace only the thermostatic cartridge (7.Q) 

follow the instructions given below:

Remove the grub screw (7.R) and pull out the 

thermostatic  cartridge  with  the  handle  (7.T) 

Based on its policy of steady development Fortis reserves the right to change the characteristics

of the products without notice and therefore the images and data contained in this catalogue may vary.

from the body. Remove the cap (7.L) from the 

assembly, loosen the grub screw (7.I) and slide 

off  the  handle  (7.M).  Remove  the  ring  (7.N), 

the lock nut (7.O) and the peg (7.P) from the 

thermostatic cartridge (7.Q).

Install  the  new  thermostatic  cartridge  (7.Q) 

into  the  faucet  housing  carefully  aligning  the 

positioning  hole  with  the  grub  screw  housing 

(7.R). Tighten the grub screw without forcing it 

so as to not cause malfunctioning or damages.

DO  NOT  move  the  bar  of  the  new  cartridge 

(7.Q) so as to not compromise the calibration.

Install  the  temperature  adjustment  lock  nut 

(7.O)  as  shown  and  screw  on  the  peg  (7.P). 

Assemble  the  handle  (7.M)  placing  the  ring 

(7.N) in between. Lock it using the grub screw 

(7.I) and complete by installing the cap (7.L).

Once completed the replacement, remove the 

stop cocks (7.S) turning them in anti-clockwise 

direction  using  a  screwdriver.  Reassemble  the 

plate (7.H), fit the handle (7.A) and lock it with 

the  grub  screw  (7.B).  Complete  the  assembly 

inserting the cap (7.C).

FIG. 08

The figure shows the faucet correctly assembled. 

Start  the  water  flow  by  rotating  clockwise  or 

anti-clockwise handle (8.A) by 90°, adjust the 

temperature using handle (8.B). 

The  thermostatic  cartridge  is  equipped  with 

a  safety  anti-scalding  retainer  set  at  100°F 

(38°C).  For  higher  temperatures  push  the 

button  on  the  adjustment  handle.  In  case  of 

hot or cold water pressure failure, the flow will 

automatically stop. 

MAINTENANCE OF THE SURFACES

Before cleaning, make sure the faucet is cold 

(heat wears the surface of the faucet down). Do 

not use products containing acids or corrosive 

substances. Wipe the faucet daily with a soft 

cloth.  Do  not  use  steel  wool  or  metal  pads, 

abrasive  sponges  or  similar  products.  Right 

after  cleaning  rinse  off  the  detergent  residues 

with cold water. Damages to the faucets caused 

by  incorrect  treatment  are  not  covered  by  the 

warranty.