INSTALLATION INSTRUCTIONS

In case of pressures over 5 BAR (~75 PSI), we 

recommend to use a pressure reducer. 

Before proceeding with the assembly, purge the 

hot  and  cold  water  pipes  so  as  to  avoid  the 

accumulation  of  dirt  and  impurities  that  could 

affect the function of the faucet.

FIG. 01

Remove  the  protection  covers  (1.A)  using  a 

screwdriver. Use the plug (1.B) if necessary.

  

FIG. 02

Fit  the  faucet  body  (2.A)  to  the  wall  with  the 

two  upper  outlets  pointing  towards  the  flow 

elements. Connect the hot water supply to the 

left inlet and the cold water supply to the right 

one.

FIG. 03 

The  depth  of  the  wall  niche  must  correspond 

(

wall  coating  included

)  to  the  tolerance  given 

by  the  MIN/MAX  references  given  on  the 

plastic cover (3.A).

Once  all  connections  have  been  carried  out, 

activate  the  faucet  at  the  working  pressure 

(we  recommend  maintaining  the  water  flow 

for  a  few  minutes  so  as  to  purge  the  system 

from any debris and/or dirt inside the piping). 

Temporarily  remove  the  protection  cover  (3.A) 

to check if there are leakages and if the system 

works  regularly,  reinstall  the  protection  cover 

(3.A) and finish the external wall surface. 

FIG. 04

Remove  the  protection  cover  (3.A)  as  shown 

in FIG. 03. With a screwdriver fasten the stop 

cocks  (4.F)  in  clockwise  direction,  loosen  the 

fitting  screw  (4.E)  using  the  proper  wrench 

and pull out the test plug (4.D). Insert the o-ring 

(4.C) and the sleeve (4.B) on the thermostatic 

body. Use a small quantity of the special grease 

included  to  lightly  lubricate  the  o-rings  of  the 

thermostatic cartridge (4.A). Insert the cartridge 

in  the  faucet  housing  carefully  aligning  the 

positioning hole with the housing of the fitting 

screw (4.E), then tighten the latter. 

Warning!

 Do not force the screw (4.E). Excessive 

tightening can affect the correct function of the 

system or damage it. The thermostatic cartridge 

is equipped with a safety anti-scalding retainer 

set  at  100°F  (38°C).  For  higher  temperatures 

push  the  button  on  the  adjustment  handle.  In 

case of hot or cold water pressure failure, the 

flow will automatically stop. With a screwdriver 

loosen  the  stop  cocks  (4.F)  in  anti-clockwise 

direction.

FIG. 05

Remove  the  protection  tape  of  the  adhesive 

sponge (5.D) and apply it on the back of the 

plate (5.C). Fit the sliding flat washers (5.B) and 

(5.A)  on  the  plate  (5.C)  and  install  it  on  the 

thermostatic body till it is flush to the wall.

FIG. 06

Control handles installation.

For the upper portion with the cartridge, follow 

the instructions given below:

Fit  the  insert  (6.L)  on  the  bar  of  the  cartridge 

so as to obtain the correct alignment once the 

handle (6.F) has been installed and lock using 

the  screw  included  (6.I).  Fit  the  handle  (6.F) 

and tighten the grub screw (6.G). Complete by 

positioning the finishing cap (6.H).

For  the  lower  portion  with  the  thermostatic 

cartridge, follow the instructions given below:

fasten the peg (6.E) on the bar of the thermostatic 

cartridge  and  install  the  handle  (6.A)  placing 

the  ring  (6.D)  in  between  without  moving  the 

bar  so  as  to  not  compromise  the  cartridge 

calibration.  Tighten  the  grub  screw  (6.B)  and 

place the finishing cap (6.C).

Water Supply

Recommended

Maximum

Minimum

Hot Water Temperature

65 C° (~150F) 

80 C° (~175F)

15 C° (~60F)

Working Pressure

3 BAR (~45PSI)

5 BAR (~75PSI)

0.5 BAR (~7PSI)

FIG. 01

FIG. 02

FIG. 06

FIG. 03

FIG. 08

FIG. 04

FIG. 05

FIG. 07

Istruz. art. 7369100.indd   4-6

26/04/11   10:08