5000RT MANUAL TELLER START UP
PROCEDURE
ONCE THE CUSTOMER AND TELLER UNITS ARE MOUNTED, THE CONTROL
CABLES ARE CONNECTED AND POWER HAS BEEN APPLIED. FOLLOW
THIS STEP BY STEP START UP PROCEDURE.
MANUAL TELLER
1 - TURN CIRCUIT BREAKER ON FOR THE CUSTOMER UNIT.
2 - CHECK AND MAKE SURE THE CUSTOMER DOOR IS CLOSED
3 - TURN THE SYSTEM ON
4 - OPEN AND CLOSE THE TELLER DOOR.
5 - THE VACUUM TURBINE SHOULD RUN FOR 6 SECONDS.
6 - ONCE THE TURBINE SHUTS OFF THE CUSTOMER DOOR SHOULD OPEN.
5 - PRESS CUSTOMER SEND SWITCH.
6 - CUSTOMER DOOR SHOULD CLOSE,
7 - THE PRESSURE TURBINE SHOULD RUN FOR 6 SECONDS.
8 - ONCE THE TURBINE SHUTS OFF THE TELLER DOOR CAN BE OPENED. IF AT
ANY TIME THE CUSTOMER DOOR OPENS CHECK FOR AN OBSTRUCTION
TO THE DOOR TRAVEL. IF THE PATH OF THE DOOR IS CLEAR ADJUST SAFETY
SWITCH SO THAT IT IS LESS SENSITIVE.
(SEE SAFETY SWITCH ADJUSTMENT
PROCEDURE)
6 - ONCE YOU MAKE SURE THAT THE SYSTEM WILL SEND THE CARRIER BACK
AND FORTH AND THE DOORS ARE WORKING CORRECTLY. ADJUST THE
TURBINE RUN TIMES SO THAT THE TURBINES RUN FOR A FULL "2" SECONDS
AFTER THE CARRIER LANDS ON THE TELLER AND CUSTOMER LANDING
PADS.
SEE TIMER ADJUSTMENT SHEET
7 - EACH SYSTEM HAS A TEST ROUTINE THAT CAN BE ACTIVATED BY
HOLDING THE UP ARROW IN ON THE CONTROL MODULE FOR 2 SECONDS.
THIS FEATURE WILL RUN FOR 15 COMPLETE TRANSACTIONS. ONCE
COMPLETE IT WILL AUTOMATICALLY STOP AND RESET. YOU CAN PRESS
THE DOWN ARROW ON THE CONTROL MODULE TO STOP THE TEST CYCLE
AT ANYTIME.
SEE TIMER ADJUSTMENT SHEET
P-27