D
5000RT AUTO TELLER OPERATIONAL
DESCRIPTION
SEND
RECALL
NIGHT LOCK
ACTIVE ONLY WHEN NIGHT LOCK IS OFF AND THE TELLER DOOR IS OPEN. WHEN PRESSED THE TELLER DOOR WILL CLOSE.
AFTER TWO SECONDS THE VAC TURBINE RELAY WILL BE ENERGIZED (SET RUNTIME WILL DETERMINED HOW LONG THE VAC
RELAY IS ACTIVE). ONCE THE TURBINE RELAY IS DEACTIVATED THE CUSTOMER DOOR WILL OPEN.
*NOTE IF THE TELLER DOOR SAFETY IS ACTIVATED AT ANYTIME DURING THE TELLER DOOR CLOSING. THE TELLER DOOR
WILL RE-OPEN AND THE SEQUENCE WILL HAVE TO BE RE-STARTED ONCE THE OBSTRUCTION IS CLEARED.
ACTIVE ONLY WHEN NIGHT LOCK IS OFF AND THE TELLER DOOR IS CLOSED. WHEN PRESSED THE CUSTOMER DOOR WILL CLOSE.
AFTER TWO SECONDS THE PRESSURE TURBINE RELAY WILL BE ENERGIZED (SET RUNTIME WILL DETERMINED HOW LONG THE
PRESSURE RELAY IS ACTIVE). ONCE THE TURBINE RELAY IS DEACTIVATED THE TELLER DOOR WILL OPEN.
*NOTE IF THE CUSTOMER DOOR SAFETY IS ACTIVATED AT ANYTIME DURING THE CUSTOMER DOOR CLOSING. THE CUSTOMER
DOOR WILL RE-OPEN AND THE SEQUENCE WILL HAVE TO BE RE-STARTED ONCE THE OBSTRUCTION IS CLEARED.
THE TELLER NIGHT LOCK IS ONLY ACTIVE WHEN THE TELLER DOOR IS OPEN. WHEN IT IS ACTIVATED THE TELLER DOOR WILL CLOSE.
AFTER 10 SECONDS THE ANTI-CONDENSATION FEATURE WILL BE TURNED ON (IF ACTIVE)(SEE PARAMETERS)
*NOTE IF THE TELLER DOOR SAFETY IS ACTIVATED AT ANYTIME DURING THE TELLER DOOR CLOSING. THE TELLER DOOR
WILL RE-OPEN AND THE SEQUENCE WILL HAVE TO BE RE-STARTED ONCE THE OBSTRUCTION IS CLEARED.
P-11