6 Appendix 1: LED States 

LED State 

Meaning 

State

Meaning 

Notes 

Mgmt Card 

ACT 

 

 

 

 

In current versions of the 
FortiSwitch, the ACT light is always 
off.  Future functionality will use 
this light to indicate state and 
activity of the external USB card. 

ACT 
MGR 

green  This is the active 

management card. 

off 

This is the 
standby 
management 
card. 

 

MC green 

All 

installed 

management 

cards up and running. 

yellow

One or both 
management 
cards are not up 
and running. 

In a system with only one 
management card the MC light 
indicates the state of that card. 

FC 

green  All fabric cards are running 

normally. 

yellow

One or more 
fabric cards are 
not running 
normally. 

If the management card's FC light 
is yellow, check the LEDs on the 
individual fabric cards to identify 
the source of the problem. 

LC 

green  All line cards are running 

normally. 

yellow

One or more line 
cards are not 
running normally.

If the management card's LC light 
is yellow, check the LEDs on the 
individual line cards to identify the 
source of the problem. 

PWR 

green  All power supplies 

powered and running 
normally. 

yellow

One or more 
power supplies 
not running 
normally. 

If the management card's PWR 
light is yellow, check the LEDs on 
the individual power supplies to 
identify the source of the problem. 

FAN 

green  All fans are running 

normally. 

off 

One or more fans 
not running 
normally. 

If the management card's FAN 
light is off, check the LEDs on the 
individual fan trays to identify the 
source of the problem. 

 

Содержание FortiSwitch-1000

Страница 1: ...FortiSwitch 1000 Version 4 0 MR1 Install Guide...

Страница 2: ...ortiBridge FortiClient FortiGate FortiGate Unified Threat Management System FortiGuard FortiGuard Antispam FortiGuard Antivirus FortiGuard Intrusion FortiGuard Web FortiLog FortiAnalyzer FortiManager...

Страница 3: ...14 3 1 Safety Considerations 14 3 2 Environmental Considerations 14 3 3 Rack Requirements 14 3 3 1 Switch Dimensions and Weight 14 3 4 Power Requirements and Redundancy 14 3 4 1 Power Overview 14 3 4...

Страница 4: ...1 LED States 22 7 Appendix 2 Updating the System Image 25 7 1 Image Update Procedure 25 7 1 1 Download Image 25 7 1 2 Load Images onto Switch 25 7 1 3 Set System Images 25 7 1 4 Reload System 26 8 App...

Страница 5: ...5 8 3 10 Supply and Chassis Ground Wiring 30 8 4 General Operational and Maintenance Guidelines 30 8 4 1 Electrical Safety 30 8 4 2 ESD 31...

Страница 6: ...Before you begin take a moment to register your Fortinet product at the Fortinet Technical Support web site https support fortinet com Many Fortinet customer services such as firmware updates technic...

Страница 7: ...al documentation on the Fortinet Tools and Documentation CD and on the Fortinet Knowledge Center 1 6 1 1 Fortinet Tools Documentation CD Many Fortinet publications are available on the Fortinet Tools...

Страница 8: ...8 2 Switch Overview 2 1 Front of Chassis Fully loaded FortiSwitch 1000 chassis with dual management cards and a combination of XFP line cards and CX4 line cards...

Страница 9: ...power supplies installed Note orientation of fan trays and power supplies The three power supplies on the left are installed with the release lever side down the three power supplies on the right are...

Страница 10: ...by connection to a laptop or other external control device The settings for the serial connection are an initialized baud rate of 115200 8 bit no parity and no flow control The table below shows the...

Страница 11: ...escription of LED states see Appendix 1 LED States on page 22 2 5 Line Card XFP FS 10G12 XFP FS 10G12 XFP A Line card with XFP optical ports optical transceivers installed ports can support either SR...

Страница 12: ...12 2 6 Fan Tray FS 1000 FANTRAY Fan tray showing release tab and handle for use in removing fan tray in case of a fan failure For full description of LED states see Appendix 1 LED States on page 22...

Страница 13: ...use in removing power supply in case of a failure requiring unit replacement indicated by a solid amber light For full description of LED states see Appendix 1 LED States on page 22 To remove power su...

Страница 14: ...s is 19 rack mountable and occupies 10RU rack units of rack space It is shipped with rack mounts installed appropriately for front mounting and includes additional screw holes to accommodate mid mount...

Страница 15: ...or unnecessary for your installation Fortinet recommends establishing circuit breaker level redundancy by putting each pair of power supplies on a separate circuit breaker For configurations where N 4...

Страница 16: ...16 N 5 12 12 12 12 N 6 12 12 12 12...

Страница 17: ...ds use of the support brackets included in the shipping crate 4 1 1 1 Support Brackets Support brackets are shipped with the FortiSwitch 1000 to facilitate the mounting of the switch packed in the gap...

Страница 18: ...onnecting a grounding wire to the grounding attachment point located on the back of the chassis and connecting the other end to an appropriate grounding attachment point in your facility The grounding...

Страница 19: ...tandard DB9 serial port on an older PC newer computers may require a USB serial converter not included The settings for the serial connection are an initialized baud rate of 115200 8 bit no parity and...

Страница 20: ...or wishes to guarantee access to the switch by a single IP address under all circumstances both management cards should be configured with the same static IP address Dynamic DHCP If the IP addresses o...

Страница 21: ...wish to configure on the active management card s management network port for out of band management of the switch 5 3 2 3 Configuring an IP Address on the Second Management Card When configuring IP...

Страница 22: ...running normally If the management card s FC light is yellow check the LEDs on the individual fabric cards to identify the source of the problem LC green All line cards are running normally yellow On...

Страница 23: ...s made synched and ready off The link is not up ACT blinking green Activity on the link off No traffic present Green ACT LED will be constantly on at high data rates STATUS green Line card functioning...

Страница 24: ...has failed and must be replaced due to fan failure overtemperature protection OTP or standby output overcurrent or undervoltage protection OCP UVP blinking green AC power is present standby output 3...

Страница 25: ...local FTP server onto which you ve downloaded the images and copy the images to the switch using standard FTP commands If using TFTP use the tftp get command to copy the images from the local TFTP ser...

Страница 26: ...file_name where file_name is the name of the new line card system image to set the system image for all line cards 7 1 4 Reload System Finish the process by resetting the switch 1 From File Mode type...

Страница 27: ...60825 2 Safety of Laser Products Part 2 Safety of Optical Fiber Communication Systems 8 1 2 EMI FCC Part 15 Class A ICES 003 Class A EN 300 386 Class A EN 55022 Class A VCCI Class A EN 61000 3 2 EN 6...

Страница 28: ...in which case the user may be required to take adequate measures 8 2 3 Canada This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme...

Страница 29: ...laser devices WARNING While Class 1 laser products are considered to be eye safe without the need for additional protection when working around the circuit boards the following general safety guideli...

Страница 30: ...e circuitry beyond the breakers When performing work maintenance on the FortiSwitch 1000 during operation SERVICE PERSONNEL should use caution as there are Hazardous Energy levels present within the c...

Страница 31: ...onnected from the power source Always verify that a circuit has been disconnected before work begins 8 4 2 ESD The FortiSwitch 1000 is sensitive to electrostatic discharge ESD It is important to take...

Отзывы: