Fortinet FortiSwitch-1000 Скачать руководство пользователя страница 20

 

– 20 – 

5.2.2 DHCP vs. Static IP Addressing 

The FortiSwitch-1000 is configured to seek an IP address via DHCP by default, but a static IP 
address can also easily be manually configured on the switch.  If the network administrator 
wishes to always access the switch by a consistent IP address, in switches with dual 
management cards Fortinet recommends manually configuring the same static management IP 
address on both cards.  Because only one management card is active at a time, the duplicate 
address does not cause an addressing conflict, and in the event of a switchover to the standby 
management card the switch may still be accessed using the same IP address, even if the switch 
is then rebooted with the second management card remaining active. 

5.2.2.1 

Management Card Switchover 

During a switchover (when the standby management card becomes the active card without 
rebooting, through either failover or use of the 

switchover

 command), the IP address of the 

newly active card will depend on the configuration of the second management card. 

Static (Manually Configured)

:  If the IP addresses of both management cards are fixed, then the 

standby card will take over the IP address of the active card when they switch roles; the IP 
address remains the same even if the cards have different static IP addresses.  On reboot, 
however, the second management card will be reset to its manually configured, fixed IP address.  
If the operator wishes to guarantee access to the switch by a single IP address under all 
circumstances, both management cards should be configured with the same static IP address. 

Dynamic (DHCP)

:  If the IP addresses of both management cards are assigned dynamically by 

DHCP, then the standby card will take the next available IP address from the DHCP server in the 
event of a switchover.  The management IP address for the switch will therefore be different after 
switchover. 

5.3 IP Address Configuration 

5.3.1 Configuring an IP Address via DHCP 

5.3.1.1 

Setting the IP Address 

By default, each FortiSwitch-1000 management card will attempt to acquire an IP address 
automatically via DHCP once the switch is running and a network cable is plugged into the 
management network port of the management card.  If the management network port of the 
active management card is connected to a network which includes a functioning DHCP server, an 
IP address for the management network port should be automatically configured on the active 
management card.  

5.3.1.2 

Finding the Assigned IP Address 

If the DHCP-assigned management IP address for the management card cannot be easily 
deduced from the network, it can be found through the CLI: 

Log into the switch (see “Logging in to the Switch” below). 

Type 

show mgmt-ip service-port

 to display configuration information for the management 

service port, including the management IP address. 

5.3.2 Manually Configuring a Static IP Address 

The process below assumes that the operator is configuring the switch for out-of-band 
management.  Inband management is disabled on the switch by default; information on 

Содержание FortiSwitch-1000

Страница 1: ...FortiSwitch 1000 Version 4 0 MR1 Install Guide...

Страница 2: ...ortiBridge FortiClient FortiGate FortiGate Unified Threat Management System FortiGuard FortiGuard Antispam FortiGuard Antivirus FortiGuard Intrusion FortiGuard Web FortiLog FortiAnalyzer FortiManager...

Страница 3: ...14 3 1 Safety Considerations 14 3 2 Environmental Considerations 14 3 3 Rack Requirements 14 3 3 1 Switch Dimensions and Weight 14 3 4 Power Requirements and Redundancy 14 3 4 1 Power Overview 14 3 4...

Страница 4: ...1 LED States 22 7 Appendix 2 Updating the System Image 25 7 1 Image Update Procedure 25 7 1 1 Download Image 25 7 1 2 Load Images onto Switch 25 7 1 3 Set System Images 25 7 1 4 Reload System 26 8 App...

Страница 5: ...5 8 3 10 Supply and Chassis Ground Wiring 30 8 4 General Operational and Maintenance Guidelines 30 8 4 1 Electrical Safety 30 8 4 2 ESD 31...

Страница 6: ...Before you begin take a moment to register your Fortinet product at the Fortinet Technical Support web site https support fortinet com Many Fortinet customer services such as firmware updates technic...

Страница 7: ...al documentation on the Fortinet Tools and Documentation CD and on the Fortinet Knowledge Center 1 6 1 1 Fortinet Tools Documentation CD Many Fortinet publications are available on the Fortinet Tools...

Страница 8: ...8 2 Switch Overview 2 1 Front of Chassis Fully loaded FortiSwitch 1000 chassis with dual management cards and a combination of XFP line cards and CX4 line cards...

Страница 9: ...power supplies installed Note orientation of fan trays and power supplies The three power supplies on the left are installed with the release lever side down the three power supplies on the right are...

Страница 10: ...by connection to a laptop or other external control device The settings for the serial connection are an initialized baud rate of 115200 8 bit no parity and no flow control The table below shows the...

Страница 11: ...escription of LED states see Appendix 1 LED States on page 22 2 5 Line Card XFP FS 10G12 XFP FS 10G12 XFP A Line card with XFP optical ports optical transceivers installed ports can support either SR...

Страница 12: ...12 2 6 Fan Tray FS 1000 FANTRAY Fan tray showing release tab and handle for use in removing fan tray in case of a fan failure For full description of LED states see Appendix 1 LED States on page 22...

Страница 13: ...use in removing power supply in case of a failure requiring unit replacement indicated by a solid amber light For full description of LED states see Appendix 1 LED States on page 22 To remove power su...

Страница 14: ...s is 19 rack mountable and occupies 10RU rack units of rack space It is shipped with rack mounts installed appropriately for front mounting and includes additional screw holes to accommodate mid mount...

Страница 15: ...or unnecessary for your installation Fortinet recommends establishing circuit breaker level redundancy by putting each pair of power supplies on a separate circuit breaker For configurations where N 4...

Страница 16: ...16 N 5 12 12 12 12 N 6 12 12 12 12...

Страница 17: ...ds use of the support brackets included in the shipping crate 4 1 1 1 Support Brackets Support brackets are shipped with the FortiSwitch 1000 to facilitate the mounting of the switch packed in the gap...

Страница 18: ...onnecting a grounding wire to the grounding attachment point located on the back of the chassis and connecting the other end to an appropriate grounding attachment point in your facility The grounding...

Страница 19: ...tandard DB9 serial port on an older PC newer computers may require a USB serial converter not included The settings for the serial connection are an initialized baud rate of 115200 8 bit no parity and...

Страница 20: ...or wishes to guarantee access to the switch by a single IP address under all circumstances both management cards should be configured with the same static IP address Dynamic DHCP If the IP addresses o...

Страница 21: ...wish to configure on the active management card s management network port for out of band management of the switch 5 3 2 3 Configuring an IP Address on the Second Management Card When configuring IP...

Страница 22: ...running normally If the management card s FC light is yellow check the LEDs on the individual fabric cards to identify the source of the problem LC green All line cards are running normally yellow On...

Страница 23: ...s made synched and ready off The link is not up ACT blinking green Activity on the link off No traffic present Green ACT LED will be constantly on at high data rates STATUS green Line card functioning...

Страница 24: ...has failed and must be replaced due to fan failure overtemperature protection OTP or standby output overcurrent or undervoltage protection OCP UVP blinking green AC power is present standby output 3...

Страница 25: ...local FTP server onto which you ve downloaded the images and copy the images to the switch using standard FTP commands If using TFTP use the tftp get command to copy the images from the local TFTP ser...

Страница 26: ...file_name where file_name is the name of the new line card system image to set the system image for all line cards 7 1 4 Reload System Finish the process by resetting the switch 1 From File Mode type...

Страница 27: ...60825 2 Safety of Laser Products Part 2 Safety of Optical Fiber Communication Systems 8 1 2 EMI FCC Part 15 Class A ICES 003 Class A EN 300 386 Class A EN 55022 Class A VCCI Class A EN 61000 3 2 EN 6...

Страница 28: ...in which case the user may be required to take adequate measures 8 2 3 Canada This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme...

Страница 29: ...laser devices WARNING While Class 1 laser products are considered to be eye safe without the need for additional protection when working around the circuit boards the following general safety guideli...

Страница 30: ...e circuitry beyond the breakers When performing work maintenance on the FortiSwitch 1000 during operation SERVICE PERSONNEL should use caution as there are Hazardous Energy levels present within the c...

Страница 31: ...onnected from the power source Always verify that a circuit has been disconnected before work begins 8 4 2 ESD The FortiSwitch 1000 is sensitive to electrostatic discharge ESD It is important to take...

Отзывы: