The FortiGate-5005-DIST Security System FortiGate-5005-DIST
interface
names
FortiGate-5005-DIST Security System Getting Started
01-30000-0414-20070615
9
FortiGate-5050 chassis
You can install one or two I/O modules in slot 1 and 2 of the FortiGate-5050 ATCA
chassis. You can also install up to three worker modules in slots 3 to 5 if two I/O
modules are being used, or four worker modules in slots 2 to 5 if one I/O module
is used. The FortiGate-5050 is a 5U chassis that contains two redundant DC
power connections that connect to -48 VDC Data Center DC power. The
FortiGate-5050 chassis also includes a hot swappable cooling fan tray. For details
about the FortiGate-5050 chassis, see the
FortiGate-5050 Chassis Guide
.
Figure 5: FortiGate-5005-DIST components installed in a FortiGate-5050 chassis
FortiGate-5005-DIST interface names
The FortiGate-5005-DIST worker web-based manager and CLI use an internal
naming convention to name FortiGate-5005-DIST interfaces. The interface names
indicate the I/O module containing the interface and also include the I/O module
front panel interface name. The naming convention is:
port<I/O_module_number>_<I/O_module_interface_name>
where:
<I/O_module_number>
is 1 for the interfaces of the primary I/O module
installed in chassis slot 1 and 2 for the interfaces of the secondary I/O module
installed in chassis slot 2. The interfaces for the secondary I/O module only
appear in the web-based manager and CLI when a secondary I/O module is
installed.
<I/O_module_interface_name>
is the name of the interface as shown on the
FortiController-5208 front panel.
Table 1 on page 10
shows the relationship between the names of the primary and
secondary module front panel interfaces and the interface names that appear on
the FortiGate-5005-DIST worker web-based manager and CLI.
1
2
2
3
4
5
SMC
1
SMC
POWER
5050SAP
SERIAL
1
SERIAL
2
ALARM
10/100
link/Act
ETH0 Service
RESET
ST
ATUS
Hot Swap
link/Act
ETH0
ETH1
10/100
5000SM
10/100
link/Act
ETH0 Service
RESET
ST
ATUS
Hot Swap
link/Act
ETH0
ETH1
10/100
5000SM
PAYLOAD OPERATION
STATUS
IPM
X 1
X 2
1/2
3/4
D15/D16
C15/C16
1
2
3
4
5
6
7
8
9
10
11
12
D
13
14
15
16
D
1
2
3
4
5
6
7
8
9
10
11
12
C
13
14
15
16
C
10/100/1000 MBPS ETHERNET ACTIVITY
DATA
CONTROL
1
2
3
4
MANAGEMENT
COM 1
COM 2
X 1
X 2
CONSOLE
ACT
ACT
LINK
LINK
FA
BRIC
BASE
USB
USB
3
4
1
2
5
6
7
8
OOS
ACC
STATUS
IPM
CONSOLE
ACT
ACT
LINK
LINK
FA
BRIC
BASE
USB
USB
3
4
1
2
5
6
7
8
OOS
ACC
STATUS
IPM
CONSOLE
ACT
ACT
LINK
LINK
FA
BRIC
BASE
USB
USB
3
4
1
2
5
6
7
8
OOS
ACC
STATUS
IPM
CONSOLE
ACT
ACT
LINK
LINK
FA
BR
IC
BASE
USB
USB
3
4
1
2
5
6
7
8
OOS
ACC
STATUS
IPM