background image

FortiController-5913C Session-Aware Load Balancing Cluster (SLBC) System Guide
10-500-259409-20160210

21

http://docs.fortinet.com/

FortiController-5913C

Basic Configuration

This section describes connecting and configuring a session-aware load balanced 
cluster (SLBC) consisting of a FortiController-5913C board installed in slot 1 and 2 or 
more workers installed in chassis slots 3 and up.

Before using this chapter, your chassis should be mounted and connected to your power 
system and the boards should be installed in the chassis. The chassis and the boards 
should also be powered up and the front panel LEDs should indicate that the boards are 
functioning normally.

This chapter includes the following topics: 

SLBC licensing

Connecting to the FortiController-5913C GUI

Connecting to the FortiController-5913C CLI

Factory default settings

Initial session-aware load balanced cluster setup

Upgrading cluster firmware

Verifying the configuration and the status of the boards in the cluster

SLBC licensing

This section describes some considerations when licensing an SLBC cluster.

FortiOS Carrier licensing

If the workers in an SLBC cluster will be running FortiOS Carrier, apply the FortiOS Carrier 
license before configuring the cluster (and before applying other licenses). Applying the 
FortiOS Carrier license sets the configuration to factory defaults, requiring you to repeat 
steps performed before applying the license.

Содержание FortiController-5913C

Страница 1: ...ortiGate 5000 series documents are available from the FortiGate 5000 page of the Fortinet Technical Documentation web site http docs fortinet com Access to Fortinet customer services such as firmware...

Страница 2: ...t is grounded This includes supply connections e g power strips not only direct connections to the branch circuit Mise la terre Assurez vous que tout l quipement est mis la terre Ceci comprend les con...

Страница 3: ...own and Removing a FortiController 5913C board 17 Resetting a FortiController 5913C board 19 Troubleshooting 20 FortiController 5913C does not startup 20 FortiController 5913C status LED is flashing d...

Страница 4: ...n 28 Customer service and support 28 Fortinet products End User License Agreement 28 Regulatory Notices 30 Federal Communication Commission FCC USA 30 Industry Canada Equipment Standard for Digital Eq...

Страница 5: ...FortiGate 5001D workers can handle up to 40 Gbps of traffic FortiGate 5001B and FortiGate 5101C workers can handle up to 10 Gbps The FortiController 5913C can also provide 40 gigabit fabric and 1 gig...

Страница 6: ...istribute sessions to workers installed in chassis slots 3 to 14 The speed of these interfaces cannot be changed You may need to use attenuators on these single or split interfaces if their optical po...

Страница 7: ...shing Amber Network activity Off No link is established B1 and B2 Green The correct cable is connected to the interface and the connected equipment has power Flashing Green Network activity at the int...

Страница 8: ...he same chassis can be added for redundancy or to increase the number of network interfaces You can also add a second chassis for chassis redundancy Table 2 FortiController 5913C connectors Connector...

Страница 9: ...ons One FortiController 5913C and up to 12 workers The FortiController 5913C receives all sessions and load balances them to the workers If the FortiController 5913C fails the cluster fails Two FortiC...

Страница 10: ...ler 5913C and up to 12 workers in each chassis The FortiController 5913C in one chassis receives all sessions and load balances them to the workers in that chassis If that FortiController 5913C fails...

Страница 11: ...m a two chassis SLBC where each chassis would include a FortiController 5913C in slot 1 and optionally a second FortiController 5913C in slot 2 You then install the workers in slots 3 and up in each c...

Страница 12: ...Controller 5913C session aware load balancing SALB FortiController 5913C system FortiController 5913C Session Aware Load Balancing Cluster SLBC System Guide 12 10 500 259409 20160210 http docs fortine...

Страница 13: ...nstall SR SFP transceivers for normal operation of FortiController 5913C B1 and B2 front panel interfaces The FortiController 5913C ships with two SR SFP transceivers You can also configure the B1 and...

Страница 14: ...right bottom of the FortiController 5913C front panel The mounting components on the left top of the front panel are the same but reversed The FortiController 5913C mounting components align the boar...

Страница 15: ...ard power on and start up correctly FortiController 5913C boards are hot swappable The procedure for inserting a FortiController 5913C board into a chassis slot is the same whether or not the chassis...

Страница 16: ...sides of the chassis slot Closing the handles draws the FortiController 5913C board into place in the chassis slot and into full contact with the chassis backplane The FortiController 5913C front pane...

Страница 17: ...ontroller 5913C mounting components described in FortiController 5913C mounting components on page 14 to remove a FortiController 5913C board from an ATCA chassis slot FortiController 5913C boards are...

Страница 18: ...s flashing and becomes solid blue 7 Open the handles to their fully open positions Opening the handles turns off the microswitch turns off all LEDs and ejects the board from the chassis slot You need...

Страница 19: ...the FortiController 5913C board to use this procedure To complete this procedure you need An ATCA chassis with a FortiController 5913C board installed An electrostatic discharge ESD preventive wrist...

Страница 20: ...ortiController 5913C board is receiving power and the handles are fully closed and you have restarted the chassis and the FortiController 5913C still does not start up the problem could be with FortiO...

Страница 21: ...hould indicate that the boards are functioning normally This chapter includes the following topics SLBC licensing Connecting to the FortiController 5913C GUI Connecting to the FortiController 5913C CL...

Страница 22: ...alancing settings By default you can connect to the FortiController 5913C GUI by browsing to https 192 168 1 99 Connecting to the FortiController 5913C CLI You can connect to the FortiController 5913C...

Страница 23: ...ler 5913C board in chassis slot 1 3 Install the workers in chassis slots 3 4 and 5 4 Power on the chassis 5 Check the chassis and board LEDs to verify that all components are operating normally 6 Chec...

Страница 24: ...as the FortiController 5913C management IP address 12 Connect FortiController 5913C front panel interface F1 to the Internet and front panel interface F2 to the internal network The workers see these...

Страница 25: ...nto the FortiController 5913C GUI going to Load Balance Status and selecting the Config Master icon beside the primary worker which is always the top entry in the Worker Blade list Using the external...

Страница 26: ...e workers in the cluster in a single operation from the worker web based manager The firmware running on all of the workers in the cluster is updated simultaneously 1 Log into the worker web based man...

Страница 27: ...ssage Running Slot 6 Status Working Function Active Link Base Up Fabric Up Heartbeat Managment Good Data Good Status Message Running Slot 8 Status Working Function Active Link Base Up Fabric Up Heartb...

Страница 28: ...ubleshooting how to articles examples FAQs technical notes and more Visit the Fortinet Knowledge Base at http kb fortinet com Comments on Fortinet technical documentation Send information about any er...

Страница 29: ...press or implied except to the extent Fortinet enters a binding written contract signed by Fortinet s General Counsel with a purchaser that expressly warrants that the identified product will perform...

Страница 30: ...this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense WARNING Any changes or modifications...