7.3.2.3 baudrate
This command specifies the communication rate of the terminal interface. The supported rates are 1200,
2400, 4800, 9600, 19200, 38400, 57600, 115200.
Syntax
baudrate {1200 | 2400 | 4800 | 9600 | 19200 | 38400 | 57600 | 115200}
no baudrate
no -
This command sets the communication rate of the terminal interface to
115200
.
Default Setting
115200
Command Mode
Line Config
7.3.2.4 exec-timeout
This command specifies the maximum connect time (in minutes) without console activity. A value of 0
indicates that a console can be connected indefinitely. The time range is 0 to 160.
Syntax
exec-timeout <0-160>
<0-160> -
max connect time (Range: 0 -160), 0: forever.
no -
This command sets the maximum connect time (in minutes) without console activity to 5.
Default Setting
5
Command Mode
Line Config
7.3.2.5 password-threshold
This command is used to set the password instruction threshold limiting the number of failed login
attempts.