Fortessa_FTK5_Instructions_Rev01
4
Keypad Lock Out – Incorrect Code Entry
Option to lock the keypad for 30 seconds on 4 incorrect code entries only, when the keypad is in the lock mode the
proximity sensor is also disabled
From quiescent state: Constant Blue LED (default)
Enter programming code (default 1234):
1 2 3 4, 1 2 3 4
(default unless changed)
Enter:
8 5 1 #
Repeat above process to toggle on or off
Change Incorrect Code Input Mode (Default 1)
Option for inputting of codes
20 Digit = 0:
You can enter up to 20 digits to enter the code without an error tone
Code Set = 1:
You can only enter 4 digits before an error tone (if programmed for 4 number code)
From quiescent state: Constant Blue LED (default)
Enter programming code (default 1234):
1 2 3 4, 1 2 3 4
(default unless changed)
Enter:
8 5 3 0 #
-
For 20 consecutively digit number entry before error tone
Enter:
8 5 3 1 #
-
For Code Set, 4 digit number entry before error tone if incorrect code entered & depending on
code length
Change Toggle Code
Toggle code once entered will permanently override the lock until the Toggle code has been re-entered (i.e. for
deliveries).
Note:
For the toggle code to operate the
Toggle Mode
will need to be set. This mode NOT suitable for failsecure locks.
From quiescent state: Constant Blue LED (default)
Enter programming code (default 1234):
1 2 3 4, 1 2 3 4
(default unless changed)
Enter:
8 5 4 X X X X #
-
(X = Bypass Code)
Change Toggle Mode (default = normal mode)
Option required if
Toggle Code
is required, when the
Toggle Code
has been entered the lock will operate and remain
unlocked until the
Toggle Code
has been re-entered
From quiescent state: Constant Blue LED (default)
Enter programming code (default 1234):
1 2 3 4, 1 2 3 4
(default unless changed)
Enter:
8 5 2 0 #
- Normal Mode
Enter:
8 5 2 1 #
- Bypass Mode
ALARM OUTPUT MODE
Alarm Output Mode
Description
0
Disabled
Alarm Output Inactive
1
Door Contact
1) Alarm output will activate if the door contact is open
2
Tamper
Alarm output will activate on tamper activation
3
1 or 2
Either Mode 1 or 2 will activate the alarm Output
From quiescent state: Constant Blue LED (default)
Enter programming code (default 1234):
1 2 3 4, 1 2 3 4
(default unless changed)
Enter:
8 5 5 X #
-
(X = Above Alarm Output Module)