18
14
15
10
16
11
12
13
If the machine was connected to an external water supply
source, disconnect the supply hose from valve no. 15.
3
4
1
Place the machine so that the boiler draining outlet is direct-
ed into the open space. Carefully open valve no. 16, paying
special attention to the steam that is coming from the out-
let. High-pressure steam jet may lead to serious burns!
5
2
Close the steam supply valves to the hoses (no. 10 and 11),
press the gun’s trigger to release any steam that still re-
mains inside hoses.
SWITCH-OFF PROCEDURE
In order to prolong your FORTADOR machine lifetime, take due care of your machine and obey the Switch-Off Procedure
as presented herein.
Switch off the machine using the button on the touch screen,
and then disconnect it from its power supply. NOTE: Failure
to observe this sequence may result in damage to the ma-
chine’s controller.
Disconnect the hoses, clean them and roll them up, be-
ing careful not to exceed the allowable bending radius
(min. 10 cm);
NOTE: Bending the hose to any radius that is
Содержание Fortador PRO S
Страница 1: ......
Страница 4: ......
Страница 22: ...22 The ball and spring in the cleaning gun need to be replaced 5 Descaling device required 4 ...
Страница 23: ...23 FAQ 14 15 10 16 11 12 13 1 2 3 6 4 1 6 4 5 8 7 10 9 Fig 2 Fig 1 ...
Страница 40: ...www fortador com ...