FUNCTION SELECTION BASIC FUNCTION
DESCRIPTIONS
ADVANCED FUNCTION DETAILS
AC
DC
F1
F2
F3
F4
F5
F6
F7
TIG
PEDAL
PANEL
REMOTE
LOCAL
TIG-HF
CONSTANT
STICK-HS
HOT START
RAMP UP
(LOCAL)
CRATER FILL
(LOCAL)
RAMP DOWN
(LOCAL)
PULSE
(BASE CURRENT)
MAIN CURRENT
HS
(STICK)
AF
(STICK)
STICK-AF
ARC FORCE
PREFLOW
POSTFLOW
TIG-HF
START ONLY
FREQUENCY
HZ
BALANCE
% EN
BASIC FUNCTIONS
TIG FUNCTIONS
STICK
SELECT
CONTROL
PULSE
PULSE
MENU
PROGRAM
HOLD
STORE
PROGRAM
ON
OFF
SELECT
ADJUST
SELECT
POWER
TEMP
FAULT
PROGRAM - CURRENT - VALUE
INPUT OK
SELECT
V
in
SELECT
MENU
TO
MODIFY
CAT# 325
PULSE
PPS
% ON
• FREQUENCY
• BALANCE
NOTE:
AC function only
FREQUENCY:
Normal AC frequency
from the wall outlet is 60
Hz, which is the number
of times the current
alternates between DCEN
and DCEP in one second.
A higher frequency (90-
240 Hz) focuses the arc.
A lower frequency (40-
90 Hz) softens the arc.
BALANCE:
Normal AC frequency
spends 50% of the time
in DCEN and 50% of the
time in DCEP. Adjusting
the Balance determines
how long the polarity
stays in DCEN. A higher
percentage of DCEN (60-
80%) creates a tighter
arc, less cleaning, and
reduces tungsten balling.
A lower percentage of
DCEN (40-60%) creates
a less-focused arc, more
cleaning, and will likely
create a ball on the top of
the tungsten.
AC
DC
F1
F2
F3
F4
F5
F6
F7
TIG
PEDAL
PANEL
REMOTE
LOCAL
TIG-HF
CONSTANT
STICK-HS
HOT START
RAMP UP
(LOCAL)
CRATER FILL
(LOCAL)
RAMP DOWN
(LOCAL)
PULSE
(BASE CURRENT)
MAIN CURRENT
HS
(STICK)
AF
(STICK)
STICK-AF
ARC FORCE
PREFLOW
POSTFLOW
TIG-HF
START ONLY
FREQUENCY
HZ
BALANCE
% EN
BASIC FUNCTIONS
TIG FUNCTIONS
STICK
SELECT
CONTROL
PULSE
PULSE
MENU
PROGRAM
HOLD
STORE
PROGRAM
ON
OFF
SELECT
ADJUST
SELECT
POWER
TEMP
FAULT
PROGRAM - CURRENT - VALUE
INPUT OK
SELECT
V
in
SELECT
MENU
TO
MODIFY
CAT# 325
PULSE
PPS
% ON
•
MENU
= Step through parameters to
make adjustments
•
SAVING PROGRAMS
= There are three
steps to saving a program:
1) Hold F7 for 3 seconds and all the LEDs
will light up
2) Select the U# you would like to save to
3) Select F7 to save parameter changes
made to program (only for U1-U20)
Use MENU to adjust parameters; Use PROGRAM to
save your adjustments in your User Defined programs
only. You cannot save your adjustments in Default
programs (S1-S10; A1-A10).