Forney 220 ST Скачать руководство пользователя страница 5

5

WWW.FORNEYIND.COM

CAUTION! 

BEFORE INSTALLING, OPERATING OR CARRYING OUT MAINTENANCE ON THE MACHINE, READ THE CONTENTS 

OF THIS MANUAL CAREFULLY, PAYING PARTICULAR ATTENTION TO THE SAFETY RULES AND HAZARDS.

In the event of these instructions not being clear, please contact your

 Forney Authorized Dealer or Forney Customer Service 1-800-521-6038.

SYMBOL

MEANING

SYMBOL

MEANING

SYMBOL

MEANING

ARC RAYS HAZARD

FIRE HAZARD

NOISE HAZARD

POISON HAZARD

ELECTRICAL HAZARD

WARNING/CAUTION

STICK (SMAW)

TIG (GTAW)

TEMPERATURE

POSITIVE DINSE

INPUT VOLTAGE

AMPERAGE

NEGATIVE DINSE

SINGLE PHASE STATIC FREQUENCY 
CONVERTER TRANSFORMER RECTIFIER

I

ON

LINE CONNECTION

DIRECT CURRENT (DC)

O

OFF

SINGLE PHASE ALTERNATING 

CURRENT (AC)

SUITABLE FOR WELDING IN AN 
ENVIRONMENT WITH INCREASED 
RISK OF ELECTRIC SHOCK

The data within this safety summary are highlights of various safety standards. It is recommended 

that you familiarize yourself with the standards listed below before beginning welding.

 

• 

ANSI Z49.1: SAFETY IN WELDING AND CUTTING - Obtainable from the American Welding Society, 550 NW Le Jeune 

Road, Miami, FL 33126 Telephone (800) 443-9353, Fax (305) 443-7559 - www.aws.org.

• 

OSHA 29 CFR, Part 1910, Subpart Q.: WELDING, CUTTING AND BRAZING - Obtainable from your state OSHA office 

or U.S. Dept. of Labor OSHA, Office of Public Affairs, Room N3647, 200 Constitution Ave., Washington, DC 20210 - 

www.osha.gov

• 

AWS F4.1: SAFE PRACTICES FOR THE PREPARATION FOR WELDING AND CUTTING OF CONTAINERS AND PIPING 

FOR WELDING AND CUTTING. - Obtainable from the American Welding Society, 550 NW Le Jeune Road, Miami, FL 

33126 Telephone (800) 443-9353, Fax (305) 443-7559 - www.aws.org.

• 

AWS A6.0. WELDING AND CUTTING CONTAINERS WHICH HAVE HELD COMBUSTIBLES - Obtainable from the 

American Welding Society, 550 NW Le Jeune Road, Miami, FL 33126 Telephone (800) 443-9353, Fax (305) 443-7559 

- www.aws.org.

• 

NFPA 70: NATIONAL ELECTRICAL CODE - Obtainable from the National Fire Protection Association, 1 Batterymarch 

Park, P.O. Box 9101, Quincy, MA 02269-9101 Telephone (617) 770-3000 Fax (617) 770-0700 - www.nfpa.org

• 

CGA Publication P-1: SAFE HANDLING OF COMPRESSED GASES IN CONTAINERS - Obtainable from Compressed 

Gas Association, 14501 George Carter Way, Suite 103, Chantilly, VA 20151 Telephone (703) 788-2700 Fax (703) 

961-1831 - www.cganet.com

•  CSA W117.2 - Code for SAFETY IN WELDING AND CUTTING. - Obtainable from Canadian Standards Association, 

178 Rexdale Blvd., Etobicoke, Ontario M9W 1R3 - www.csa.ca

•  ANSI Z87.1 - SAFE PRACTICE FOR OCCUPATION AND EDUCATIONAL EYE AND FACE PROTECTION - Obtainable 

from the American National Standards Institute, 11 West 42nd St., New York, NY 10036 Telephone (212) 642-900, Fax 

Symbols Legend

Safety Summary

Principal Safety Standards

Содержание 220 ST

Страница 1: ...ITEM 430 REV 08 08 2019 220 ST STICK TIG ARC WELDER OPERATING MANUAL ENGLISH...

Страница 2: ...solutions to our customer s needs Above all our employees will provide the same respect and caring attitude within the organization as they are expected to share with every Forney customer Our goal wi...

Страница 3: ...epair or replace defective products at no charge to you When you call Forney s Technical Service department you will speak to a trained product and application expert Forney s primary goal is to get y...

Страница 4: ...URCE CONNECTION 10 GENERATORS 11 EXTENSION CORDS 11 VENTILATION 11 ADDITIONAL WARNINGS 11 GETTING TO KNOW YOUR WELDER 12 DESCRIPTION 12 WELDER LAYOUT AND CONTROLS 12 OPERATION 14 PERFORMANCE DATA PLAT...

Страница 5: ...your state OSHA office or U S Dept of Labor OSHA Office of Public Affairs Room N3647 200 Constitution Ave Washington DC 20210 www osha gov AWS F4 1 SAFE PRACTICES FOR THE PREPARATION FOR WELDING AND C...

Страница 6: ...es are not strictly observed THE WELDING ARC PRODUCES VERY BRIGHT ULTRAVIOLET AND INFRARED LIGHT THESE ARC RAYS WILL DAMAGE YOUR EYES AND BURN YOUR SKIN IF YOU ARE NOT PROPERLY PROTECTED To reduce the...

Страница 7: ...improve ventilation in the welding area Do not resume welding if physical discomfort persists Fire Prevention FIRE OR EXPLOSION CAN CAUSE DEATH INJURY AND PROPERTY DAMAGE To reduce these risks read un...

Страница 8: ...sher nearby High Frequency Radiation High Frequency H F can interfere with radio navigation safety services computers and communication equipment It is the user s responsibility to have a qualified el...

Страница 9: ...und shoulders or any other part of the body when they are plugged into the welder Do not modify any wiring ground connections switches or fuses in this welding equipment Wear welding gloves to help in...

Страница 10: ...tings label of your welder The main power supply voltage should be within 10 of the rated main power supply voltage Too low a power supply voltage may cause poor welding performance Too high a power s...

Страница 11: ...electing an extension cord appropriate for use with your specific welder Select a properly grounded extension cord that will mate directly with the AC power source receptacle and the welder INPUT POWE...

Страница 12: ...there is a general welding or machine fault 5 SECONDARY PARAMETER KNOB SELECTOR for the function selection a PULSE Hz Frequency Pulses per second or Hertz b PULSE On Balance at Peak Amperage Peak c A...

Страница 13: ...13 WWW FORNEYIND COM 1 1a 5a 1b 5b 1c 5c 4 3 2 REAR VIEW OF FORNEY 220 ST PRO WELDER 11 12 13 FRONT VIEW OF FORNEY 220 ST PRO WELDER 6 7 8 9 5 10...

Страница 14: ...o the duty cycle Various duty cycles at other amperages are listed on your data plate Example Data Plate If you exceed the duty cycle of the welder the thermal protection system will engage shutting o...

Страница 15: ...ATIVE DINSE SOCKETS accordingly Direct current electrode positive DCEP or direct current reverse polarity DCRP electrode holder in POSITIVE DINSE SOCKET ground clamp in NEGATIVE DINSE SOCKET Most elec...

Страница 16: ...c Use pedal or torch to adjust output amperage while working REMEMBER TO CLOSE THE VALVE ON THE GAS CYLINDER IMMEDIATELY AFTER ALL WELDING IS COMPLETED Welding Tips Always weld clean dry and well prep...

Страница 17: ...GSTEN DCEN Th La Ce AC La Ce AC Pure 040 10 50A 20 40A N A 1 16 40 120A 30 170A 30 90A 3 32 90 200A 60 180A 40 120A 1 8 150A 130A 100 200A This machine has a 7 pin Amphenol style connection for connec...

Страница 18: ...able does not provide all possible solutions only those possibilities considered likely to be common faults PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION All LEDs OFF No output power Fan not operating No i...

Страница 19: ...ircuit breaker trips Machine is drawing too much amperage due to use of larger size electrode Use a smaller electrode Machine is not the only piece of electrical equipment on the circuit Make sure the...

Страница 20: ...ORNEYIND COM Machine Parts Diagram Replacement Parts List NO PART NUMBER ITEM DESCRIPTION 1 85668 Ground 50 Dinse 2 85670 Electrode Holder 50 Dinse 3 85516 120 230V Power Adaptor Plug 4 5084 Expert Te...

Страница 21: ..._ ________________________________________________________________________________ ________________________________________________________________________________ ____________________________________...

Страница 22: ..._ ________________________________________________________________________________ ________________________________________________________________________________ ____________________________________...

Страница 23: ..._ ________________________________________________________________________________ ________________________________________________________________________________ ____________________________________...

Страница 24: ...Forney Industries Inc 2057 Vermont Drive Fort Collins CO 80525 1 800 521 6038 www forneyind com...

Отзывы: