![Fornelli PIA 60 INDUZIONE Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/fornelli/pia-60-induzione/pia-60-induzione_user-manual_2320294017.webp)
Installation and Operating Manual
Installation and Operating Manual
HOBS
15
CONNECTION TO ELECTRIC MAINS
Before proceeding with connection of the hob
to electric mains, please, make sure, that:
– specifications of the electric mains corre-
spond to the figures specified on the na-
meplate of the hob, attached in the lower
part of the hob;
– the electric mains is equipped with reliable
and proper grounding system in conformi-
ty with applicable standards and regulati-
ons.
WARNING!
Since this device consumes significant
power (7,2 kW), it MUST BE connected
to a dedicated power supply line, having
conductor cross-section of at least
4 mm
2
.
The appliance must be connected to the elec-
tric mains in strict compliance with current
standards and regulations.
Wiring diagram is given on Figure 10 below:
Fig
. 10
380V 2N H07RN-F 5G1. 5mm
2
3
4
2
220V
white
1
blue
brown
green-yellow
black
N
N
L2
PE
LI
1
2
3
brown
blue
green-yellow
220-240V
1N
220-240V
H07RN-F 3G4 . 0mm
2
4
L
N
PE
380V 2N H07RN-F 5G1. 5mm
2
3
4
2
220V
white
1
blue
brown
green-yellow
black
N
N
L2
PE
LI
1
2
3
brown
blue
green-yellow
220-240V
1N
220-240V
H07RN-F 3G4 . 0mm
2
4
L
N
PE
When the hob is connected directly to
the mains, the connection must be made
through the circuit breaker, which ensures
at least 3 mm gap between open contacts.
This is not required in the event that the hob is
connected to mains using wall outlet and plug,
in which case these wall outlet and plug must
be easily accessible in order to be quickly di-
sengaged.
The plug and the cable used for connection
of the hob, must meet all the applicable stan-
dards and be able to withstand the electric
power consumed by the hob (see Max. Con-
sumed Power, kW section).
Grounding wire (yellow-green) shall not be di-
sconnected by the circuit breaker.
In any event power cord of the hob must be
laid so that in none of its points the temperatu-
re would higher than the ambient temperature
by more than 50 °C.
In the event that the power cord needs to be
replaced, the replacement power cord must
ensure safe operation of the hob in view of the
given electric power consumption and opera-
ting temperature.
Содержание PIA 60 INDUZIONE
Страница 1: ...HOBS PIA 60 INDUZIONE INDUCTION HOB COMPANY SPECIALIZING IN BUILT IN OVENS AND HOBS EN User s manual...
Страница 16: ...Installation and Operating Manual HOBS 14 Fig 9 Fig 8 Fig 7 Larger scale diagram is given on Page 21...
Страница 20: ...Installation and Operating Manual HOBS 18 PIA 60 INDUZIONE Installation Diagram...
Страница 23: ......
Страница 24: ...www fornelli tech com...