background image

 

 

17 

 

7

 

CONTACTS 

For spare parts please contact Formula Air Group. 

 

Formula Air France Nord 

Zac de la Carriere Dorée 
BP 105, 
59310 Orchies, France 
Tel : +33 (0) 320 61 20 40 

contact‐nord@formula‐air.com 

Formula 

Air Nordic 

Södra Vallviksvägen 12 
352 57 Vaxjo, 
Sweden 
Tel : +46 (0)8 12 41 01 24 

info‐scan@formula‐air.com 

Formula Air Belgium 

Rue des Dizeaux 4 
1360 Perwez, 
Belgium 

Tel: +32 (0) 81 23 45 71 

info‐be@formula‐air.com 

 

 

 

Formula Air France Est 

2, rue Armand Bloch 
25200 Montbéliard, 
France 
Tel : +33 (0) 381 91 70 71 

contact‐est@formula‐air.com 

Formula 

Air 

Russia 

Нижний Новгород 
Россия

 

Tel : +7920008 88 75 

info‐ru@formula‐air.com 

Formula Air Germany 

Dr. Oetkerstrasse 10 
54516 Wittlich, 
Germany 
Tel 49 (0) 65 71 26 98 6‐0 

info‐de@formula‐air.com 

 

 

 

Formula Air France Sud 

Chemin de Peyrecave 
09600 Regat, 
France 
Tel : +33 561 66 79 70 

contact‐sud@formula‐air.com 

Formula Air The Netherlands 

Bosscheweg 36 
5741 SX Beek en Donk, 
The Netherlands 
Tel : +31 (0) 45 492 15 45 

info‐nl@formula‐air.com 

Formula Air Baltic 

P. Motiekaicio g. 3 
77104, Šiauliai, 
Lithuania 
Tel: +370 41 54 04 82 

info‐lt@formula‐air.com 

 

 

 

Formula Air France Ouest 

6 Avenue des Lions 
44800 Saint Herblain, 
France 
Tel : +33 (0) 251 89 90 75 

contact‐ouest@formula‐air.com 

Formula Air Export 

Rue des Dizeaux 4 
1360 Perwez, 
Belgium 
Tel : +32 (0) 81 23 45 71 

customerservice@formula‐air.com  www.formula‐air.com 

 

 

 

NOTE : All drawings and references contained within this manual are non-contractual and are subject to 

change without prior notice at the discretion of the Formula Air group and its partners. 

Содержание BADA000010

Страница 1: ...BADA ATEX Non Return Valve Maintenance Manual...

Страница 2: ...necting the non return valve 9 2 3 Precautions for a proper use 9 3 INSTALLATION 10 3 1 Maintenance 10 3 1 1 Cleaning and checking the inside of the non return valve 11 4 ATEX CERTIFICATION 12 4 1 Pot...

Страница 3: ...valves are built in 3 mm thick 16mo3 steel powder coated RAL 5010 and the flap of HB400 Hardox Formula Air Non return valves fulfill all relevant requirement to be used safely in an explosion hazardou...

Страница 4: ...e 3 Non Return Valve in closed configuration After an explosion and due to pressure oscillations the valve could re open To avoid the re opening a safety lock system keeps the valve closed long enough...

Страница 5: ...current cleaning of the filter If this is the case the installation distance and reverse flow pressure should be checked to reduce the effect on the non return valve Figure 4 Locking system inside th...

Страница 6: ...A000023 454 720 760 785 157 52 3 94 BADA000024 504 770 810 835 157 52 3 106 BADA000025 554 820 860 885 157 52 3 118 BADA000026 604 870 910 935 157 52 3 130 BADA000010 653 985 1021 1090 247 71 3 169 BA...

Страница 7: ...operation maintenance and repair in areas with danger of explosions may only be carried out by qualified personnel Ensure that no tools nuts and bolts or assembly parts remain in the machine during a...

Страница 8: ...devices this excludes e g suppression and venting with reclosing vent devices The maximal speed flow is 25 m s 1 The maximum dust concentration in the ducting is witout the limit The product has to be...

Страница 9: ...to be performed by qualified personnel Use the right equipment and costumes and do not work alone 2 1 Valve installation direction For a right installation the air flow direction in normal working co...

Страница 10: ...open the inspection panel while the installation is running During maintenance keep the system disconnected and all the electrical equipment turned off The valve should not be placed in an environmen...

Страница 11: ...the process interruption CAUTION The installation connection start up and maintenance of the non return valves must be performed by qualified personnel Use the right equipment clothing and individual...

Страница 12: ...panel as shown in Figure 12 Figure 12 opening inspection panel Step 2 Clean the inside of the valve and check the condition of every part Step 3 Close the inspection as shown in Figure 13 If necessar...

Страница 13: ...occurrence of an explosive atmosphere Zone 0 A place in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas vapor or mist is present continuously...

Страница 14: ...f the noticed monitoring body 1026 not for equipment category 3 Ex Explosive protection symbol ATEX II Equipment group II for use above ground 1 Equipment category Category 2 2 Equipment category Cate...

Страница 15: ...FTZ 18 ATEX 0141X II D St 1 EN 16447 2014 II 1D 2D Ex h IIIB T850 C Da Db Please refer to user manual before installation Figure 15 Name label used for every ATEX Non Return Valve 200 1000 Explanatio...

Страница 16: ...manual using improperly parts or the whole device supplied using not authorized spare parts manipulation the device by non qualified personnel violation of any safety norm regarding design constructi...

Страница 17: ...erials depending on their type steel stainless steel rubber foams etc Recyclable parts must be disposed in the appropriate containers or brought to a local recycling company The rubbish must be collec...

Страница 18: ...ermany Tel 49 0 65 71 26 98 6 0 info de formula air com Formula Air France Sud Chemin de Peyrecave 09600 Regat France Tel 33 561 66 79 70 contact sud formula air com Formula Air The Netherlands Bossch...

Отзывы: