4. Inspect the Mirrors

Closely inspect the mirrors for any signs of particles, dust or residue. Use a 

bright light or a flashlight to illuminate the mirrors.

If it is necessary to clean the mirror, carefully position the galvo block as 

shown. Use the swab to gently rotate the mirror so that the surface is more 

easily accessible. Gently wipe the mirror from the base of the mirror to the 

end of the mirror. Rotate the swab and wipe again.

WARNING: DO NOT EXERT EXCESSIVE PRESSURE ON THE GALVO MIRROR. 

NEVER TOUCH THE MIRROR WITH ANYTHING OTHER THAN A PEC-PAD. 

5/7

DO NOT COPY OR REDISTRIBUTE THIS INFORMATION

5. Wipe Y Galvo Mirror

Содержание GALVO

Страница 1: ...ace mirrors in the Form 1 can cause scratches and irreversible damage Exercise extreme caution when the mirror is exposed Contact support formlabs com with any questions Formlabs Customer Support can...

Страница 2: ...screws under the cover Some machines may also have two silver countersunk screws along the rear edge on the bottom of the Form 1 Carefully remove the back panel after all screws have been removed Prop...

Страница 3: ...m the Form 1 frame WARNING DO NOT REMOVE OR TAMPER WITH ANY OTHER SCREWS IN THE GALVO BLOCK ADJUSTING ANY OTHER SCREWS WILL MOVE THE PRINTER OUT OF CALIBRATION Cut a strip about 1cm wide out of PEC PA...

Страница 4: ...PAD over to the side Begin wrapping the PEC PAD tightly down and around the shaft as shown Secure the PEC PAD strip at the bottom of the shaft with another piece of small tape When finished it should...

Страница 5: ...n the galvo block as shown Use the swab to gently rotate the mirror so that the surface is more easily accessible Gently wipe the mirror from the base of the mirror to the end of the mirror Rotate the...

Страница 6: ...own Use the swab to gently rotate the mirror so that the surface is more easily accessible Gently wipe the mirror from the base of the mirror to the end of the mirror Rotate the swab and wipe again On...

Страница 7: ...ecure the galvo block to the Form 1 frame Reconnect the galvanometer cables and the connect the laser to the main board Then reinstall the Form 1 back panel 9 Plug in Cables Laser Y Galvanometer X Gal...