formlabs GALVO Скачать руководство пользователя страница 4

4/7

5. Close the printer

DO NOT COPY OR REDISTRIBUTE THIS INFORMATION

Fold the end of the PEC-PAD over to the side. Begin wrapping the PEC-PAD 

tightly down and around the shaft as shown.  

 

Secure the PEC-PAD strip at the bottom of the shaft with another piece of 

small tape. When finished, it should look similar to the one shown.

Apply a small amount of isopropyl alcohol to the PEC-PAD swab.

Содержание GALVO

Страница 1: ...ace mirrors in the Form 1 can cause scratches and irreversible damage Exercise extreme caution when the mirror is exposed Contact support formlabs com with any questions Formlabs Customer Support can...

Страница 2: ...screws under the cover Some machines may also have two silver countersunk screws along the rear edge on the bottom of the Form 1 Carefully remove the back panel after all screws have been removed Prop...

Страница 3: ...m the Form 1 frame WARNING DO NOT REMOVE OR TAMPER WITH ANY OTHER SCREWS IN THE GALVO BLOCK ADJUSTING ANY OTHER SCREWS WILL MOVE THE PRINTER OUT OF CALIBRATION Cut a strip about 1cm wide out of PEC PA...

Страница 4: ...PAD over to the side Begin wrapping the PEC PAD tightly down and around the shaft as shown Secure the PEC PAD strip at the bottom of the shaft with another piece of small tape When finished it should...

Страница 5: ...n the galvo block as shown Use the swab to gently rotate the mirror so that the surface is more easily accessible Gently wipe the mirror from the base of the mirror to the end of the mirror Rotate the...

Страница 6: ...own Use the swab to gently rotate the mirror so that the surface is more easily accessible Gently wipe the mirror from the base of the mirror to the end of the mirror Rotate the swab and wipe again On...

Страница 7: ...ecure the galvo block to the Form 1 frame Reconnect the galvanometer cables and the connect the laser to the main board Then reinstall the Form 1 back panel 9 Plug in Cables Laser Y Galvanometer X Gal...