Maintenance |
41
1. Tap the back section of the Fuse Sift’s diagram to turn off the vent.
2. Unscrew and remove the six thumb screws that hold the filter grate in place.
3. Pull out the filter grate that sits above and around the filter.
4. Pull out and remove the filter that sits behind the grate.
5. Dispose of the filter according to your local environmental regulations.
6. Insert a new filter with the gasket pressed against the sheet metal receiver.
7. Place the filter grate back in place above and around the filter, then tighten the six
thumb screws until hand tight.
6.5.5
Replacing the sifter mesh
Clumps of nylon can accumulate in the mesh screen below the collection grate, eventually
preventing reclaimed powder from passing through to be collected. Formlabs recommends
replacing the sifter mesh after every 200 hours of use.
To remove and replace the sifter mesh:
1. Remove the collection grate to gain access to the sifter mesh beneath.
2. Turn the turnbuckles to release the sifter mesh.
3. Place the new sifter mesh within the Fuse Sift and refasten all the turnbuckles.
4. Place the sifter grate back over the sifter mesh.