Using the Form Cure
5.1
Operational Environment
Operate the Form Cure in a well-ventilated room with a temperature of 18–28 °C (64–82 °F).
For optimal performance, do not exceed this range.
5.2
Post-Curing
5.2.1
Insert Washed and Dried Prints
Fully dry all solvent off of printed parts after
washing. Check all surfaces, because curing
non-dried parts may trap solvent inside the
part, prevent parts from strengthening, and
affect quality. Once parts are dry, lift the cover,
then distribute parts on the round turntable.
Place parts with the most even spacing
possible to allow light and heat to reach all
areas. Gently close the cover.
The Form Cure contains a heater to
enable post-curing. Take care when
inserting and removing parts from the
Form Cure, because the metal turntable
may be hot.
5.2.2
Set Post-Cure Time and Temperature
Turn the knob to navigate the display menu. Press the knob to select a feature or setting.
Select the time and temperature, and then select
Start.
The LEDs will activate and the timer
will start once the heater has reached the target temperature. Once a cure cycle has started,
use the display or open the cover to pause post-curing.
See
support.formlabs.com
or
5.4 Time and Temperature Settings
for specific post-cure
settings for each resin type.
The printed part must be in the Form Cure while it heats. If the part is not placed in
the Form Cure until preheating is complete, it may cause cracking.
WARNING
NOTICE