background image

11

EN

DE

FR

NL

FOREST SHUTTLE

®

 S/M/L RECEIVER

    

SHUTTLE

®

 S 

SHUTTLE

®

 M 

SHUTTLE

®

 L

Part #  

5232000000  

5232000003  

5232000001

Voltage Shuttle

®

:  

24Vdc  

24Vdc 1 

00 - 240V~ 50 - 60Hz 0.8A

Max. power:  

40W  

72W 4 

0W

Torque:  

1Nm  

1.5Nm  

1Nm

Speed 1:  

14 cm/s  

14cm/s  

14 cm/s

Speed 2:  

17 cm/s  

17cm/s  

17 cm/s

Max. curtain weight:  

40kg (no curves)  

70kg (no curves)  

40kg (no curves)

Length:  

20cm (7.9”)  

25 (10”)  

28cm (11”)

Net. weight motor:  

700 gr.  

980gr.  

930 gr.

Protection degree:  

IP20  

IP20  

IP20

Max. running time
(in one direction):  

240 sec.  

240 sec.  

240 sec.

Sound level:  

< 40dB  

<40dB  

< 40dB

Ambient temperature:  

0 - 40⁰C (32 - 104⁰F)   0 - 40⁰C (32 - 104⁰F)   0 - 40⁰C (32 - 104⁰F)

Relative humidity:  

10 – 80%  

10 – 80%  

10 – 80%

Maximum useable altitude
above sea level:  

2000m (6561ft.)  

2000m (6561ft.)  

2000m (6561ft.)

Certification & Marking:   CE  

CE  

CE

24V ADAPTOR:

    

SHUTTLE

®

 S: 

SHUTTLE

®

 M:

Model:  

ZDA240150  

ZF120A-2403000

Voltage input:  

100 - 240V~ 50 - 60Hz 0.8A  

100 - 240V~ 50 - 60Hz 1.2A

Voltage output:  

24Vdc  

24Vdc

Insulation class: 

II  

II

Certification & Marking:   CE, cULus, FCC, CCC  

CE, cULus, FCC, CCC

If another power supply is used or a central power supply, each Shuttle

®

 S must be protected with a 

2.5A slow fuse. Each Shuttle

®

 M Receiver must be protected with a 4A slow fuse.

   40,6  

 

   56,8  

 

   10,7  

 

   38,4  

 

   19,5  

 

   81  

 

   39,3  

 

   78,4  

 

   75  

 

   18,1   

   32  

 

   81  

 

   49  

 

   22  

 

   41,5  

 

   56,8  

 

   33,5  

 

   38,5  

 

200 mm

R200

H

B1

B2

SHUTTLE S

225 mm

77 mm

49 mm

SHUTTLE M

 REC

270 mm

77 mm

49 mm

SHUTTLE L 

305 mm  77 mm 

49 mm

B2

B1

H

TECHNICAL SPECIFICATION

Содержание 5232000000

Страница 1: ...FOREST SHUTTLE S M L RECEIVER EN DE FR NL INSTALLATION MANUAL FOREST SHUTTLE S M L RECEIVER other languages instructional video ...

Страница 2: ...2 CONTENTS page QUICK START 3 INSTALLATION 4 CONFIGURATION OVERVIEW 6 CONNECTING TO HOME AUTOMATION SYSTEMS 8 CONFIGURATION MASTER SLAVE FUNCTION 9 TECHNICAL SPECIFICATIONS 11 CONTACT SUPPORT 12 ...

Страница 3: ...tions are reset and have to be set again 1 Push the curtain towards the CLOSE position until the motor takes over 2 The motor will open the curtain automatically When it is reached the yellow LED flashes 3 Pull the curtain to the desired OPEN position this can be done as long as the yellow LED is flashing 4 Let the curtain hang at the desired OPEN position until the yellow LED goes off 5 Ready for...

Страница 4: ...o the power socket of Shuttle L SHUTTLE S M RECEIVER Connect the 24V plug into the socket of the Shuttle S M Rec and connect the AC plug to the wall socket Pass the connecting cable through the strain relief this prevents the cable from being pulled out Attach the adaptor to the Shuttle or wall 1 2 3 4 5 Setting the end limits of the FOREST SHUTTLE S M L Receiver Before setting the end limits the ...

Страница 5: ...ines the end position After the motor has determined the end position the curtain will automatically return to the OPEN position When the curtain has reached the OPEN position it will stop automatically yellow LED4 is on Do you still want to adjust the stack back Then adjust it by hand or by remote control You have to do this within 10 seconds If the curtain is not moved for 10 seconds the yellow ...

Страница 6: ...e installation LED1 LED2 LED3 configuration button LED4 CONFIGURATION Number of times to press LEDs 1234 function factory default 1 speed low 2 speed high 3 RF 433 4 reset endlimits 5 dry contact pulse 6 dry contact continous 7 dry contact single switch 8 touch impulse sensitive high 9 touch impulse sensitive low 10 touch impulse off 11 IR channel 1 12 IR channel 2 13 IR channel 3 14 IR channel 4 ...

Страница 7: ...e led blinks 3 times and goes OFF When a Forest remote is programmed to the Shuttle the end limits can also be reset by pressing 5 times the P button and 5 times the STOP button on the remote End limits of all Shuttles in range on this channel will reset end limits DRY CONTACT INPUTS 5 6 7 Standard input is pulse contact To set to continuous or single switch press button 6 or 7 times respectively ...

Страница 8: ...tle will stop moving the curtain MODES Pulse when short contact is made the curtain will open or close fully default setting Continuous the curtain will move as long as the contact is made mostly used for Home Automation Systems Single button switch door bell principle either one of the four inputs will act as following open stop close stop open stop close stop etc To change this setting see page ...

Страница 9: ...he two motors Connect port 1 motor A to port 1 motor B with a UTP FTP cable or an 8 wire flat cable Program the MASTER motor push the configuration button 17 times shortly LEDS 1 to 4 light up one more time with each push After 17 presses once more push the button and hold for 4 seconds LEDs 1 to 4 will move with every press see configuration overview on page 6 Program the SLAVE motor press the co...

Страница 10: ...r 17 presses once more press the button and hold for 4 seconds Then push the button again for 4 seconds LED 1 will blink three times and go off see configuration overview on page 6 Program the SLAVE motor Press the configuration button 19 times shortly LEDS 1 to 4 will move with every press see configuration overview on page 6 After 19 presses once more press the button and hold for 4 seconds LED ...

Страница 11: ...2 104 F Relative humidity 10 80 10 80 10 80 Maximum useable altitude above sea level 2000m 6561ft 2000m 6561ft 2000m 6561ft Certification Marking CE CE CE 24V ADAPTOR SHUTTLE S SHUTTLE M Model ZDA240150 ZF120A 2403000 Voltage input 100 240V 50 60Hz 0 8A 100 240V 50 60Hz 1 2A Voltage output 24Vdc 24Vdc Insulation class II II Certification Marking CE cULus FCC CCC CE cULus FCC CCC If another power s...

Страница 12: ...st Group Nederland B V This product is not suitable for use by children it is not a toy Keep the remote control out of the reach of children at all times Frequently examine the installation for imbalance and signs of wear or damage Forest Group does not assume liablity for resulting damages to persons animals and or property defects labour on location service calls reinstallation or expenses invol...

Отзывы: