7 User instructions
Answering a call
When a call is received, the ‘phone will alert the user with the call
tone set in your ‘phone, and the picture will pop up. Press either the
“Accept” to speak to the caller, or press “Decline” to stop the alert.
If you accept the call you can hear the caller, but need to hold the
mic key for your voice to be heard. Release to listen to the
caller.
Image captur and video recording
During a call, a single snapshot can be saved by pressing the
the
icon on the screen. Likewise, the
and
icons may
be used to start and stop recording a video clip. The file will be
found on your device picture memory.
Monitoring the camera
Any device with the APP loaded can connect with the camera. Load
and register the APP in the normal way. When the APP loads, it will
show the live camera picture. You may also listen to the panel using
and speak through it with
icons.
Door release code
The door release relay can be operated any time your phone is
connected to the call panel, whether in answering a call, or
connecting by opening the APP. To unlock the door, enter the 4
digit code on the soft keypad, then close the APP.
The code can be changed on the APP by authorised ‘phones. Click
‘
●●●
’ on the top right corner of your device. Click ‘OFF’ in outdoor
call in option. Click “
unlock password setting
” to get the edit screen.
You will need to enter the old release code (password) and the new
release code. Click “
setting
” to exit.
5b
… by an Android device
Search for the panel WiFi (5.1 & 5.2)
Open the ControlCam APP on you phone and click “Enter now”. Select
“Add a Device” followed by “Add a New Device”. The phone searches
for WiFi signals, then displays a list. Panel numbers begin GIDxxx. This
number is also printed and as a QR code on the rear of the panel, and
can be entered manually later. Click the panel ID.
Now click “Start Configuring”. Select your router’s WiFi, and enter its
password, normally printed on the back of the router. Wait 100 secs.
“Configuration is successful, please add the device to the phone”.
Click OK to confirm. Now enter user name & password….
Device ID
“Front Door”
a name chosen by user
GID
aw14d62154
copied from label or paired
User
admin
default is admin, change later
Password
1234
default is 1234, change later
Click OK to confirm data. Click
‘
●●●
’ on the top right corner and
click ‘ON’ in the call-in options.
This device is ready.
6 Keypad programming
Mastercode reset
This procedure allows a new mastercode to be set. It does not change
existing access codes or the system password. Switch off the power,
then power up again while holding the * button. Release * and press
* once more. Enter your new mastercode the same length as the old
mastercode. Another long beep indicates the mastercode is accepted.
Factory reset
This procedure clears all the access codes, resets the relay time to 1
sec, and resets the mastercode to 1234. Follow the master-code reset
above, but using the # button instead of the * button.
Programming examples
The codelock is programmed using a codelock mastercode. It can be
set from 2 to 6 digits long. Mastercode is denoted in the examples
below by
xxxx
. Five examples are shown.
-
Press
*
xxxx
‘Beep’
(
enter
programming mode)
--1--------------------------------------------------
-
Press
99
‘Beep’
(enter memory 99)
-
Press
4
‘Beep’
(
sets code
length to 4 digits)
--2--------------------------------------------------
-
Press
00
‘Beep’
(enter memory 00)
-
Press
03
‘Beep’
(
sets relay time
to 3 secs)
--3--------------------------------------------------
-
Press
34
‘Beep’
(enter memory 34)
-
Press
2580
‘Beep’
(
set code
in memory 34 to 2580)
--4--------------------------------------------------
-
Press
37
‘Beep’
(enter memory 37)
-
Press
*
‘Beep’
(
delete code
in memory 37)
--5--------------------------------------------------
-
Press
#
‘Beep’
(delete code mode)
-
Press
1397
‘Beep’
(
delete code
1397 from any memory)
----------------------------------------------------
-
Press
*
‘Beep’
(
exit
programming)
To exit programming, press * key, or leave for 30 secs.
Forematic
9 Vanalloys Estate
QPF14-210
Stoke Row
Henley RG9 5QW
www.forematic.com
Declaration of Conformity
We hereby declare, that roller door opener F-210 has been manufactured
in accordance with the following standards or normative documents
EN 60335-2-95: 2004
EN 60335-1/A13: 2008/A2: 2006
EN 62233: 2008
EN 61000-3-2: 2006, + A1: 2009 +A2: 2009
EN 61000-3-3: 2008
EN 55014-1: 2006 +A1: 2009 EN 55014-2: 1997 +A2: 2008
EN 50371: 2002
In accordance with the provisions of the following directives
98/37/EC
Machinery Directive with amending directives
2006/95/EC LV Directive
2004/108/EEC EMC Directive
1999/5/EC
R&TTE Directive
23.03.2015
– FOREMATIC
9 Vanalloys Estate, Stoke Row,
Mr H WYNN JONES
Henley RG9 5QW, United Kingdom
Director