background image

 

 

                                         - 3 - 

 

i

460 ip intercom       

Installation manual    

doc. 

K42

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

     7   User instructions 

 

Answering a call 

 

When a call is received, the ‘phone will alert the user with the call 
tone set in your ‘phone, and the picture will pop up. Press either the 
“Accept” to speak to the caller, or press “Decline” to stop the alert. 
If you accept the call you can hear the caller, but need to hold the 

mic key for your voice to be heard. Release to listen to the 

caller. 

 
Image captur and video recording 

 

During a call, a single snapshot can be saved by pressing the 

the

 icon on the screen. Likewise, the 

 and 

 icons may 

be used to start and stop recording a video clip. The file will be 
found on your device picture memory. 
 

Monitoring the camera 

 

Any device with the APP loaded can connect with the camera. Load 
and register the APP in the normal way. When the APP loads, it will 
show the live camera picture. You may also listen to the panel using 

 and speak through it with 

icons.  

 

Door release code 

 

The door release relay can be operated any time your phone is 
connected to the call panel, whether in answering a call, or 
connecting by opening the APP. To unlock the door, enter the 4 
digit code on the soft keypad, then close the APP. 
 
The code can be changed on the APP by authorised ‘phones. Click 

●●●

’ on the top right corner of your device. Click ‘OFF’ in outdoor 

call in option. Click “

unlock password setting

” to get the edit screen. 

You will need to enter the old release code (password) and the new 
release code. Click “

setting

” to exit. 

 
 

 

 
 

     5b  

… by an Android device 

 

Search for the panel WiFi (5.1 & 5.2) 

 

Open the ControlCam APP on you phone and click “Enter now”. Select 
“Add a Device” followed by “Add a New Device”. The phone searches 
for WiFi signals, then displays a list. Panel numbers begin GIDxxx. This 
number is also printed and as a QR code on the rear of the panel, and 
can be entered manually later. Click the panel ID. 
 
Now click “Start Configuring”.  Select your router’s WiFi, and enter its 
password, normally printed on the back of the router. Wait 100 secs. 
“Configuration  is  successful,  please  add  the  device  to  the  phone”.  
Click OK to confirm. Now enter user name & password….  

 

       

Device ID

   

“Front Door”  

 

a name chosen by user

 

       

GID

      

 

aw14d62154    

copied from label or paired

 

       

User  

   

 

admin   

 

 

default is admin, change later 

       

Password

   

1234 

 

 

 

default is 1234, change later

  

 

Click OK to confirm data.  Click 

●●●

’ on the top right corner and 

click ‘ON’ in the call-in options.   

 

 

This device is ready. 

 
 

     6   Keypad programming 

 

Mastercode reset 

 

This procedure allows a new mastercode to be set. It does not change 
existing access codes or the system password. Switch off  the power, 
then power up again while holding the * button. Release * and press 
* once more. Enter your new mastercode the same length as the old 
mastercode. Another long beep indicates the mastercode is accepted. 

 

 
Factory reset 

 

This procedure clears all the access codes, resets the relay time to 1 
sec, and resets the mastercode to 1234. Follow the master-code reset 
above, but using the # button instead of the * button.  
 

Programming examples 

 

The codelock is programmed using a codelock mastercode. It can  be 
set  from  2  to  6  digits  long.  Mastercode  is  denoted  in  the  examples 
below by 

xxxx

. Five examples are shown. 

 

 
 

Press

   

xxxx

     

‘Beep’   

(

enter

 programming mode)  

 

 

--1-------------------------------------------------- 

Press

    

99

          

‘Beep’   

(enter memory 99) 

Press

    

4

           

‘Beep’   

(

sets code

 length to 4 digits)  

 

 

--2-------------------------------------------------- 

Press

    

00

          

‘Beep’   

(enter memory 00) 

Press

    

03

          

‘Beep’   

(

sets relay time

 to 3 secs)  

 

 

--3-------------------------------------------------- 

Press

     

34

 

    

‘Beep’    

(enter memory 34)

 

Press

     

2580   

‘Beep’      

(

set code

 in memory 34 to 2580)

 

 

 

 

--4-------------------------------------------------- 

Press

     

37

 

    

‘Beep’    

(enter memory 37)

 

Press

     

*   

 

‘Beep’      

(

delete code

 in memory 37)

 

 

 

 

--5-------------------------------------------------- 

Press

     

#

       

‘Beep’    

(delete code mode)

 

Press

     

1397   

‘Beep’      

(

delete code

 1397 from any memory)  

 

 

---------------------------------------------------- 

Press

     

*

           

‘Beep’    

(

exit

 programming)

  

 

 
To exit programming, press * key, or leave for 30 secs.

 

 
 
 
 

Forematic

 

9 Vanalloys Estate  

 

 

 

 

 

 

QPF14-210

 

Stoke Row 
Henley  RG9 5QW  

 

     

 

 

www.forematic.com                  

 

 

Declaration of Conformity 

 

We hereby declare, that roller door opener F-210 has been manufactured 
in accordance with the following standards or normative documents  
 
   EN 60335-2-95: 2004 
   EN 60335-1/A13: 2008/A2: 2006 
   EN 62233: 2008    
   EN 61000-3-2: 2006, + A1: 2009 +A2: 2009 
   EN 61000-3-3: 2008 
   EN 55014-1: 2006 +A1: 2009   EN 55014-2: 1997 +A2: 2008 
   EN 50371: 2002 
 
In accordance with the provisions of the following directives 
   98/37/EC      

Machinery Directive with amending directives 

   2006/95/EC         LV Directive 
   2004/108/EEC    EMC Directive 
   1999/5/EC   

 R&TTE Directive 

 
 

 

 

 

 

 

 

 

 

 

 

23.03.2015 

– FOREMATIC 

9 Vanalloys Estate, Stoke Row,   

 

Mr H WYNN JONES 

Henley RG9 5QW, United Kingdom   

Director 

 

 

 

 

 
 
 
 
 
 
 

 
 
 
 

 

Отзывы: