background image

Accessory

  

more than 1

1

2

″          

1

″ 

     

3/4

″ 

     

1/4

ʺ″

 

 

     

1/8

″ 

   

3/32

″ 

less than 3/32

 

Diameter

 

 

(40mm) (28 – 40mm) 

(18 – 28mm) 

(8 – 18mm) 

(4 – 8mm) 

(2 – 4mm) 

(less than 2mm)

Rotation Speed

 – RPMs

RECOMMENDED APPROXIMATE BUR SPEEDS

50,000

45,000

40,000

35,000

30,000

25,000

20,000

15,000

10,000

5,000

0

ERROR CODES

Error  

Code Status 

 

Cause

E1, E5  Circuit Protection 

- Circuit of control is malfunctioning.

 

   

- Handpiece or foot control cords are unplugged, defective or broken. 

E2 

Overload Protection 

- Handpiece has been operated under an overload condition.

E3 

Handpiece Protection 

- Control unit received a lower voltage than specified.

E4 

Stall Protection 

- Collet chuck is open.

 

   

- Handpiece is mechanically stalled.

 

Voltage Protection 

- Voltage Selector switch is set for the wrong voltage.

E6 

Overheating Protection 

- Handpiece has been operated under a high load condition or too long.

 

   

- Control unit has been exposed to an excessively  

 

   

warm environment (more than 100°F)

This tool should be grounded while in use to 

protect the operator from electric shock. The tool is 

equipped with an approved 3-conductor cord and a 

3-prong grounding type plug to fit the proper 

grounding receptacle. The green (or green and 

yellow) conductor in the cord is the grounding wire. 

Never connect the green (or green and yellow) wire 

to a live terminal. If your unit is for use on less than 

150 volts, it has a plug that looks like sketch A 

below. An adapter (sketches B and C) can be used 

for connecting plugs as shown in sketch A to 

2-prong receptacles. The green colored rigid ear, 

lug, etc., extending from the adapter must be 

connected to a permanent ground such as a 

properly grounded outlet box. 

Some jurisdictions, 

including Canada, prohibit the use of 3 to 2 

prong adapters. Where prohibited, they should 

not be used. 

Use only 3-wire extension cords that 

have 3-prong grounding type plugs and 3-pole type 

plugs and 3-pole receptacles that accept the tool’s 

plug. Always disconnect the power cord before 

servicing the tool. Never use in an area where 

flammable vapors are present.

Store your Foredom power tools in a DRY, 

clean, dust-free area, and out of the reach 

of children.

USING PROPER GROUNDING PROCEDURES. 

Handpiece Maximum Torque - 11.3 oz-in / 8 N-Cm

Control units Maximum Watts Output - 240 Watts

Содержание K.1040

Страница 1: ...Foot Control H MH 140 Handpiece K 1040 High Speed Rotary Brushless Micromotor For Your Safety Read this Manual before operating your Foredom Micromotor Power Tool Always wear eye protection while usin...

Страница 2: ...lance Inspect each accessory for cracks or flaws before use ALWAYS insert the shank or arbor of an accessory or mandrel into the collet or chuck of the hand piece as far as possible in order to provid...

Страница 3: ...with the Speed Dial but range of speed will be controlled by the Foot Control REGULATING SPEED Use the Speed Dial to vary the speed of the handpiece from minimum to maximum when the Hand Indicator li...

Страница 4: ...nd a wrench with a triangular shaped hole which fits over the collet Collet Wrench The Nosecone Wrench is used to tighten the nosecone and is also used with the collet wrench to remove the collet Acce...

Страница 5: ...un thread the collet counterclockwise 4 Once the collet is loosened unthread it completely by hand Unthread Tighten Collet removed Nosecone Wrench Nosecone Wrench Accessory Accessory 6 Tighten with t...

Страница 6: ...ed for wood carving it should be cleaned after every use A cloth with a small amount of alcohol solution can be used to clean the outside of the handpiece if neces sary Do not use any other cleaning f...

Страница 7: ...quipped with an approved 3 conductor cord and a 3 prong grounding type plug to fit the proper grounding receptacle The green or green and yellow conductor in the cord is the grounding wire Never conne...

Страница 8: ...warranty lasts or the exclu sion or limitation of incidental or consequential damages so the above limitations or exclusion may not apply to you At our sole option repair replacement or refund will b...

Отзывы: