Accessory
more than 1
1
⁄
2
″
1
″
3/4
″
1/4
ʺ″
1/8
″
3/32
″
less than 3/32
″
Diameter
(40mm) (28 – 40mm)
(18 – 28mm)
(8 – 18mm)
(4 – 8mm)
(2 – 4mm)
(less than 2mm)
Rotation Speed
– RPMs
RECOMMENDED APPROXIMATE BUR SPEEDS
50,000
45,000
40,000
35,000
30,000
25,000
20,000
15,000
10,000
5,000
0
ERROR CODES
Error
Code Status
Cause
E1, E5 Circuit Protection
- Circuit of control is malfunctioning.
- Handpiece or foot control cords are unplugged, defective or broken.
E2
Overload Protection
- Handpiece has been operated under an overload condition.
E3
Handpiece Protection
- Control unit received a lower voltage than specified.
E4
Stall Protection
- Collet chuck is open.
- Handpiece is mechanically stalled.
Voltage Protection
- Voltage Selector switch is set for the wrong voltage.
E6
Overheating Protection
- Handpiece has been operated under a high load condition or too long.
- Control unit has been exposed to an excessively
warm environment (more than 100°F)
This tool should be grounded while in use to
protect the operator from electric shock. The tool is
equipped with an approved 3-conductor cord and a
3-prong grounding type plug to fit the proper
grounding receptacle. The green (or green and
yellow) conductor in the cord is the grounding wire.
Never connect the green (or green and yellow) wire
to a live terminal. If your unit is for use on less than
150 volts, it has a plug that looks like sketch A
below. An adapter (sketches B and C) can be used
for connecting plugs as shown in sketch A to
2-prong receptacles. The green colored rigid ear,
lug, etc., extending from the adapter must be
connected to a permanent ground such as a
properly grounded outlet box.
Some jurisdictions,
including Canada, prohibit the use of 3 to 2
prong adapters. Where prohibited, they should
not be used.
Use only 3-wire extension cords that
have 3-prong grounding type plugs and 3-pole type
plugs and 3-pole receptacles that accept the tool’s
plug. Always disconnect the power cord before
servicing the tool. Never use in an area where
flammable vapors are present.
Store your Foredom power tools in a DRY,
clean, dust-free area, and out of the reach
of children.
USING PROPER GROUNDING PROCEDURES.
Handpiece Maximum Torque - 11.3 oz-in / 8 N-Cm
Control units Maximum Watts Output - 240 Watts