Lubricate Pump
Coat areas of pump that might rust, such as areas with damaged paint, with a light film of oil.
Use a silicone spary lubricant and lightly lubricate controls.
STORAGE
Drain Fuel Tank and Fuel injection pump assembly
•
For long term storage (over 90 days) drain fuel from fuel tank and fuel injection pump assembly.
•
•
•
Turn the fuel valve to the “off” position.
Place a funnel underneath the fuel valve to catch fuel as it drains into a bucket.
Turn the
fuel valve to the “on” position and allow all fuel to drain. (Fig 1
5
)
Turn the fuel valve to the “off” position.
Replace the inline fuel filter.
Store the drained fuel in a suitable place.
•
•
•
Storage Location
•
If pump is stored with diesel, store pump in a well-ventilated area away from anything that operates with an open
fl
a
me
.
To prevent leakage, store pump on a level surface with the Fuel Valve lever in the
“OFF”
position.
•
To prevent rust, avoid storing pump in areas with high humidity.
•
To protect from dust, cover with a tarp or plastic sheet.
Storage cover could be flammable. Let engine cool before covering pump.
Remove from Storage
See pg 10 Pre-Operation Checklist
Transporting Pump
•
Turn the fuel valve to the “OFF” postion.
•
To prevent fuel leakage, keep pump level while transporting.
WARNING!