Ford FD6700S Скачать руководство пользователя страница 5

5

SAFETY RULES

Do not wear loose clothing or gloves.

Remove jewelry or anything else that could be caught in moving parts.

Tie back or wear protective head covering to contain long hair.

WARNING!

Starter and other moving parts can catch on clothing, jewelry, and hair.

Keep engine away from flammable objects and other hazardous materials.

death.

The fuel and its vapors used to power this unit are highly flammable and could explode resulting in serious injury or

Never fill or drain fuel tank indoors.
Never overfill fuel tank.  If fuel spills, move the unit at least 30 feet away from the spill and wipe up any remaining fuel


on the unit before starting the engine.

Never smoke while operating or fueling this unit.
Never operate or store this unit near an open flame, heat, or any other ignition source.


Generator should have at least 5 feet of clearance from buildings or other equipment during operation.  
Keep engine free of grass, leaves, or grease which are flammable.


When adding or draining fuel, unit should be turned off for at least 2 minutes to cool before removing fuel cap.  If unit 
has been running then the fuel cap is under pressure, remove slowly.

To keep fuel from spilling, secure unit so it cannot tip while operating or transporting.

When transporting unit,  disconnect the spark plug wire and make sure the fuel tank is empty with the fuel shutoff 
valve turned to the off position. 

WARNING!

Never exceed generator’s wattage / amperage capacity.  This could damage the generator 
and / or connected electrical devices.

• 

Check operating voltage and frequency requirements of all electrical devices prior to plugging them into the generator.

Always start the engine and let it stabilize before connecting any electronic devices.

Disconnect all electronic devices before stopping the engine.

Never start or stop engine with electrical devices plugged in to the receptacles. Failure to do 
so could damage the generator and / or connected electrical devices.


Allow hot components to cool before touching.

Use caution around the muffler, cylinder, and other engine parts as they can be extremely hot.

Avoid contacting hot areas of this unit.

W

W

WARNING!

W

W

WARNING!

W

W

WARNING!

W

W

WARNING!

W

W

WARNING!

Содержание FD6700S

Страница 1: ...MODEL FD6700S www fordpower cc Diesel Generator OPERATOR S MANUAL FD7200S FD7200S T FD6700S T...

Страница 2: ...System 13 Operation 13 How to Start Engine 14 Battery Charger for Electric Starter 14 Grounding the Generator 13 How to Stop Engine 15 Receptacles and Extension Cords 15 Don t Overload Generator 16 Wa...

Страница 3: ...order parts receive warranty assistance or other services inquiries you can contact us by internet at www fordpower cc Record the following information bellow for service or warranty assistance PULSA...

Страница 4: ...r alone Safety Instructions Using a generator indoors WILL KILL YOU IN MINUTES Carbon monoxide gas is a poisonous odorless gas that can cause headache confusion fatigue nausea fainting Never use indoo...

Страница 5: ...unit should be turned off for at least 2 minutes to cool before removing fuel cap If unit has been running then the fuel cap is under pressure remove slowly To keep fuel from spilling secure unit so...

Страница 6: ...eed Only operate generator on a level surface Always connect the nut and ground terminal on the frame to an appropriate ground source Generator must be properly grounded to prevent electrocution WARNI...

Страница 7: ...ng Stud F Meter Frequency Current Battery Voltage C Socket CEE 3P N T FEATURES A B C D E F Three Phase Single Phase A G H E D I D Outlets H Socket CEE 2P T G Main Circuit Breaker I Circuit Breaker Tim...

Страница 8: ...Cover Plate V Maintenance Door S Oil Plug M Fuel Tank Q Air Filter W Battery P Pressure Support Bar R Mechanical Switch Engine T Oil Drain Plug U Maintenance Door Lock X Wheels Y Muffler FEATURES O P...

Страница 9: ...acking List Check all loose parts to the following list Contact your dealer if any loose parts are not included 8 10 10 12 Description Qty Generator 1 Quick Start Guide 1 4 Cycle engine oil SAE10W 40...

Страница 10: ...touch any part of the frame Repeat these steps for the Black Terminal Attaching Battery Cable See Fig 3 Open Top Cover Plate See Fig 2 Play open the lock See Fig 2A Open the top cover plate upwards Se...

Страница 11: ...ON SHIELD EYES EXPLOSIVE GASES CAN CAUSE BLINDNESS OR INJURY NO SPARKS FLAMES SMOKING SULFURIC ACID CAN CAUSE BLINDNESS OR SEVERE BURNS FLUSH EYES IMMEDIATLEY WITH WATER GET MEDICAL HELP FAST WARNING...

Страница 12: ...a level surface wipe dipstick clean then reinsert dipstick without rethreading Adding Checking Engine Oil See Fig 4 You must add engine oil before first operating this generator Always checkengine oi...

Страница 13: ...ution The ground terminal located on the back of the generator frame must always be used to connect generator to a driven ground rod Connect the ground terminal to the driven ground rod with a No 8 AW...

Страница 14: ...r Keep the generator battery fully charged and ready to use in order to avoid generating unit can t start W W WARNING Turn the START ON OFF switch Key to the START position to attempt to start the Eng...

Страница 15: ...11 OPER A TION Receptacles and Extension Cords Only use high quality well insulated grounded extension cords in good condition with generator receptacles Follow each load manufacturer s power rating...

Страница 16: ...atts to the total Rated Watts in step 1 Keep total load within generator s power capacity Operating voltage and frequency requirement of all electronic equipment should be checked prior to plugging th...

Страница 17: ...onnected electrical devices Check operating voltage and frequency requirements of all electrical devices prior to plugging them into the generator 17 Power Management Start engine without anything con...

Страница 18: ...ns where temperatures drop to 40 F 4 C Diesel and crankcase ventilation pipe lines may appear to freeze In order to prevent Diesel and crankcase ventilation pipe lines may appear to freeze To prevent...

Страница 19: ...ule 19 Engine Oil Air Filter Fuel Filter Oil Filter Fuel Tank Check Level Replace Check Clean Replace Replace Clean Verify Gas Level Each Use O O O Every Month or Each 20 Hrs Every 3 Month or Each 50...

Страница 20: ...temperature range expected see Fig 14 Fig 14 W W CAUTION Used oil should be disposed of at an approved disposal site See your local oil retailer for more information 50 122 10W 40 SAE40 Fuel Recommend...

Страница 21: ...install air filter so that it seals and replace air filter cover 21 Cooling System Cooling system should only be serviced by an authorized dealer Fuel pump and fuel injector system should only be serv...

Страница 22: ...in the fuel system drain the fuel from the tank and carburetor before storing the unit for long periods of time This will help prevent starting problems in the future If the unit is stored with fuel a...

Страница 23: ...ove any debris if obstructed For short term storage Less than 1 month No storage procedure required storage 1 to 3 month Fill with fresh diesel fuel storage more than 3 month Draining the fuel tank Re...

Страница 24: ...l crankcase to proper oil level place generator on a level surface 8 Low oil level 9 Rich fuel mixture 9 Contact service department 10 Loss of engine compression 10 Contact service department 11 Dead...

Страница 25: ...DIAGRAMS 25...

Страница 26: ...onents and labor 12 Month Limited coverage on generator engine and alternator components parts only Personal use means personal residential household use or recreational use by the retail consumer Com...

Страница 27: ...inal purchaser Refurbished used demonstration or floor models are not covered by this warranty Products purchased from on line auction websites such as ebay are not covered under this warranty Product...

Отзывы: