Diverter Valve Installation
l
Fix the diverter valve with PRV assembly to the faucet and fasten the
screws to the faucet properly with a Philips screwdriver. (The PRV is
2
factory adjusted for 1.5 kg / cm .) In case of external threaded type
faucet, the tap adapter of the diverter valve should be removed and
then directly fix the diverter valve into the faucet.
l
Ensure free movement of diverter valve knob for normal water supply.
l
Keep the product near a drain facility.
l
Remove the screws of the front cover of the product.
l
Slide out the front cover from the chassis.
Sediment Filter Flushing
l
Disconnect the sediment filter cartridge outlet port tubing.
l
Connect ¼” blue tube to the outlet and keep the other end of the
¼” tube at the drain facility.
l
Connect the installation tube assembly to the ‘Water In’ port of the
product (ensure both sides of the tubing to the connectors are
inserted fully).
l
Open the diverter valve and flush the sediment filter till the
manufacturing debris is fully driven out and outlet water
becomes clear.
l
Close the diverter valve, disconnect the blue tubing fixed for
flushing and connect back the interconnecting tube as earlier.
6