Step-by-step guide
to pure drinking water
10
Indications & Controls
• Power ON /OFF indication by LED.
• Purification Process indication by LED.
• UV Fault indication LED & Beep sound.
• Power saver mode indication by LED and Beep.
• A weight sensor is provided to stop the filtration process when the storage
tank is full.
• LPS is provided to switch off the unit in case of unavailability of supply water.
• D-Calcifier to prevent scale deposition on QG Glass.
Working of the unit
1. Fit cord plug of the unit into the power socket and turn the switch ON to start
the unit.
2. When the power to the unit is turned ON, the dual LED would glow RED for 5
sec indicating that power is on. After 5 sec. it will get off.
3. Then after a wait of 25 sec. dual LED would start to glow in GREEN and three
beeps will sound which indicates the enabling of solenoid valve and thereby
pure water starts flowing into the storage tank.
NOTE – If water pressure is low then LPS would shut down the Lamp and SV.The
LED would remain off in this state. As soon as the water supply resumes the unit
will start afresh.
4. When the tank gets full the weight sensor switch would trigger the
deactivation of Solenoid Valve and thus stop the water flow to the tank. If the
water from the tap is not drawn then after 10 min. the unit would go into power
saver mode (i.e. UV lamp will turn off) which is indicated by three beeps and
blinking of LED in green color at the completion of 10 min. of idle state.
5. Fault condition: In case of any error in UV system, the LED would start blinking
in RED color alongwith beep sound. During this condition unit will not deliver
water in storage tank .The beep will stop after 10 min but blinking continues.