background image

Blood Pressure

1.  Stretch your arm in front of  you with your palm 

facing up.

2.  Slide and place the cuff  onto your arm with the 

air tube and artery mark region (in red) toward 
the lower arm. Make sure the cuff  is about the 
same height as the location of  your heart. Wrap 
and tighten the cuff  above your elbow. 
 
 
 
 
 
 

3.  Leave a little free space between the arm and 

the cuff, you should be able to fit 2 fingers 
between them. 

4.  Sit down for at least 10 minutes before 

measuring.

5.  Place your elbow on a flat surface. Relax your 

hand with the palm facing up. 
 
 
 
 

6.  Press the power button. All the LCD symbols 

will appear. Then the cuff  will begin to inflate 
automatically.

7.  The heart symbol will flash when a pulse is 

detected during the inflation.

8.  After the measurement, the monitor displays the 

systolic pressure, diastolic pressure and pulse 
rate.

Performing a Test

Blood Glucose

1.  Wash your hands.
2.  Insert lancet into FORA lancing device and 

close.

3.  Insert test strip into the meter.
4.  Press lancing device against fingertip and click 

the release button. 
 
 
 
 
 
 

5.  Apply the blood sample to the absorbent hole of  

the test strip. 
 
 
 
 
 
 
 
 

6.  Wait 5 seconds for results.
7.  Eject the test strip from the meter to ensure the 

results are automatically uploaded to the 24/7 
HealthView Telehealth system using the cellular 
signal.

118-160

Normal

118-160

Normal

Содержание D40g

Страница 1: ...D40g Blood Pressure and Blood Glucose Monitoring System Quick Start Guide EN ...

Страница 2: ...0g Meter Information Intended for single patient use only Meter will switch off automatically if left idle for 3 minutes Meter should transmit data automatically For more information on manual data transmission or signal quality check please refer to the user manual Blood Glucose Strips Strips have an expiration date Please check strip container for the expiration date before using Strips expire 9...

Страница 3: ...wer button All the LCD symbols will appear Then the cuff will begin to inflate automatically 7 The heart symbol will flash when a pulse is detected during the inflation 8 After the measurement the monitor displays the systolic pressure diastolic pressure and pulse rate Performing a Test Blood Glucose 1 Wash your hands 2 Insert lancet into FORA lancing device and close 3 Insert test strip into the ...

Страница 4: ...ter handling the meter lancing device and test strips to avoid contamination This device has been validated to withstand up to 6 000 cleaning and disinfecting cycles using the recommended disinfecting wipes See the user manual for more information For additional information on the D40g please refer to the user manual FAQ How does the D40g work The D40g measures the systolic and diastolic blood pre...

Страница 5: ...ine at 1 888 307 8188 Error Code Err 1 Err 2 Appears when the batteries cannot provide enough power for a test Replace or recharge the batteries immediately PCL Err 30 Unable to connect to the service PCL Err 40 PCL Err 41 PCL Err 42 PCL Err 43 PCL Err 44 PCL Err 45 PCL Err 48 PCL Err 49 No response from the server What It Means Solution Err 3 Err 4 Err 5 No pulse rate detected or the pulse rate i...

Отзывы: