45
7-5-3. Commands Setting Value
Command 1 - PowerOn,<Device>,CHK,0 CRLF
No setting value (fixed to 0). Use this command to verify whether the USF-106UDS_DC-12G
module is powered on and can accept commands.
Command 2 - Dynamic Range CONV,<Device>,Gamma Curve Enable,<Value>
[CR][LF]
Item
Settings
Description
Dynamic Range
Conversion
0: Bypass
1: Operate
Sets DRC (Dynamic Range Conversion)
operation. If set to Bypass, DRC is bypassed.
Command 3 Dynamic Range CONV,<Device>,EOTF DeGamma,<Value> [CR][LF]
Item
Settings
Description
Input
Gamma Curve
(EOTF)
1: SDR 2.2 BT.1886
2: SDR 2.4 BT.1886
3: HLG BT.2100
4: HLG (RGB SG1.2)
5: HLG (RGB SG1.4)
6: ST 2084 (PQ)
7: SDR 2.2 BT.709
8: S-Log3
9: Canon Log 2
10: SDR 2.4 BT.1886
Specifies the input signal gamma curve.
Command 4 - Dynamic Range CONV,<Device>,OETF Gamma, <Value> [CR][LF]
Item
Settings
Description
Output
Gamma Curve
(OETF)
1: SDR 2.2 BT.1886
2: SDR 2.4 BT.1886
3: HLG BT.2100
4: HLG (RGB SG1.2)
5: HLG (RGB SG1.4)
6: ST 2084 (PQ)
7: SDR 2.2 BT.709
8: S-Log3
9: Canon Log 2
10: SDR 2.4 BT.1886
Sets the output gamma curve.
Command 5 - Color Space CONV, <Device>,In Color Space, <Value> [CR][LF]
Item
Settings
Description
Input
Color Space
0: Rec. ITU-R BT. 709
1: Rec. ITU-R BT. 2020
2: S-Gamut/Gamut3(User1)
3: User2
4: User3
5: User4
6: User5
Specifies the input signal color space.