4. Web GUI 

Status parameters of USF-105DDA-12G can be displayed on the Web display if the module is installed 
in  a  USF-212AS  or  USF-105AS  frame.    SNMP  monitoring  is  also  available.    Refer  to  the 
USF-212AS/USF-105AS Operation Manual for details on displaying the Web GUI window. 
 

NOTE 

USF-105DDA-12G  does  not  support  simultaneous  Web  GUI  access  from  multiple  PCs.  To 
simultaneously monitor a USF-105DDA-12G from multiple PCs, use the SNMP function. 

 
 

4-1. WEB Display Information 

Start the Web GUI and click on a USF-105DDA-12G from slot 1 to 12 of USF-212AS/USF-105AS to 
open the window as shown below. 
 

 

 

 

Module Information 

Item 

Description 

Slot 

Slot no. of the USF-212AS/USF-105AS in which USF-105DDA-12G is 
installed. 

S/N 

Serial number of the USF-105DDA-12G. 

MAC Address 

MAC address of the USF-105DDA-12G. 

Version 

Software version of the USF-105DDA-12G. 

IP Address 

IP address of the USF-105DDA-12G. 

Installed Cards 

Indicates whether or not the front and rear modules are matched. 

Matched

Correct modules are installed. 

Mismatched

:  An incorrect rear module is installed. Install the correct rear 

 

module. 

CPU Temperature  Temperature of the CPU on the USF-105DDA-12G. 

Video Input 

Displays video input status 

Detected

Normal video input. 

Not Detected

:  No video input, or input level is low. 

Input Status Trap 

Sets the SNMP trap setting when monitoring USF-105DDA-12G via SNMP 
manager. 

Enable

:  Sends input status traps. 

Disable

:  Sends no traps. 

Input Signal 
(SD/HD/3G/12G) 

Displays the bit rate of SDI input: 

SD (270Mbit/sec), HD (1.5Gbit/sec),  

 

3G (3.0Gbit/sec), 12G (12.0Gbit/sec)

 

Not Detected

No input signal 

Mode 

Displays the re-clock function mode. 

 

Содержание USF-105DDA-12G

Страница 1: ...USF 105DDA 12G Digital Distribution Amplifier 1st Edition OPERATION MANUAL ...

Страница 2: ...ircuitry exposed could result in electric shock fire hazards or a unit malfunction Potential Hazards Caution If abnormal odors or noises are noticed coming from the unit immediately turn the power off and disconnect the power cord to avoid potentially hazardous conditions If problems similar to the above occur contact an authorized service representative before attempting to operate the unit again...

Страница 3: ...e packing list below Check to ensure no damage has occurred during shipment If damage has occurred or items are missing inform your supplier immediately USF 105DDA 12G ITEM QTY REMARKS USF 105DDA 12G 1 USF 105DDA 12G Front Module USF 105DDA 12G Rear Module DVD ROM 1 Operation Manual PDF Screw for Rear Module Installation 2 This Product can be installed into the following frames USF 212AS USF 105AS...

Страница 4: ... 2 Features 5 2 Panel Descriptions 6 2 1 Front Panel 6 2 2 Rear Panel 6 3 DIP Switch Settings 7 4 Web GUI 8 4 1 WEB Display Information 8 4 2 syslog Functions 9 5 About SNMP 10 6 Specifications and Dimensions 11 6 1 Specifications 11 6 2 External Dimensions 11 ...

Страница 5: ...SDI SD SDI and DVB ASI and is capable of producing up to 5 outputs from 1 input 1 2 Features Installs into USF frames 1 input 5 distribution outputs Supports SDI 12Gbps 3Gbps 1 5Gbps and 270Mbps signals Automatic 12G 3G HD SD SDI equalizer and re clock functions Detection of input signal and identification of 12Gbps 3Gbps 1 5Gbps 270Mbps Supports DVB ASI 270Mbps signal SNMP monitoring ...

Страница 6: ...1 5Gb s LED Lights green when input SDI signal is 1 5G b s 5 270Mb s LED Lights green when input SDI signal is 270M b s 6 DIP switch Sets input signal switching 7 USB connector Used to upgrade USF 105DDA 12G software Do not connect USB devices 2 2 Rear Panel USF 105DDA 12G SDI IN 1 2 3 4 5 SDI OUT Name Description SDI IN SDI signal input Accepts an SD HD 3G 12G SDI signal SDI OUT 1 5 SDI signal ou...

Страница 7: ... No Function Setting Factory Setting OFF ON 1 ON Do not change the settings 2 OFF Do not change the settings 3 OFF Do not change the settings 4 OFF Do not change the settings 5 Reclock Reclock Bypass Reclock ON Normal use settings 6 OFF Do not change the settings 7 OFF Do not change the settings 8 OFF Do not change the settings ...

Страница 8: ...lled S N Serial number of the USF 105DDA 12G MAC Address MAC address of the USF 105DDA 12G Version Software version of the USF 105DDA 12G IP Address IP address of the USF 105DDA 12G Installed Cards Indicates whether or not the front and rear modules are matched Matched Correct modules are installed Mismatched An incorrect rear module is installed Install the correct rear module CPU Temperature Tem...

Страница 9: ...log messages by checking the address The IP address is the same as the SNMP trap address Refer to the USF 212AS USF 105AS Operation Manual for details on setting the SNMP trap address Facility Sets syslog logging facilities in Local 0 through Local 7 Header Message Sets syslog header messages up to a maximum of 63 alphanumeric characters Factory setting USF 105DDA 12G Input Video Detect Sets detec...

Страница 10: ...umber 1756 3 0 INTEGER Soft Version usf105Dda12gVersion 4 0 OCTET STRING Slot Number usf105Dda12gSlotNumber 1 12 5 0 INTEGER CPU Temperature usf105Dda12gCpuTemperature degree Celsius 6 0 INTEGER Input Video Status usf105Dda12gInputStatus 1 cannotDetect 0 not Detected 1 detected 7 0 INTEGER Input SDI Bit Rate usf105Dda12gSdiRate 1 cannotDetect 0 not Detected 1 sdi SD 2 sdi HD 3 sdi 3G 4 sdi 6G 5 sd...

Страница 11: ...x 100m 5C FB equivalent cable HD SDI Max 100m 5C FB equivalent cable SD SDI Max 200m 5C 2V equivalent cable SNMP SNMP Monitoring available USF 212AS USF 105AS frame required SNMP version v2C Temperature 0 ºC to 40 ºC Humidity 30 to 90 no condensation Power 12V DC Supplied by USF frame Power Consumption 4 2VA 4 2W Dimensions Front Module 106 W x 357 D mm Rear Module 114 W x 20 2 H mm Weight 220 g R...

Отзывы: