10
5. About SNMP
The USF-105DDA-12G can be remotely monitored using an external SNMP monitoring system that
supports SNMPv2C. MIB (Management Information Base) files that are required for SNMP monitoring
systems can be downloaded from the Web GUI. (
Refer to the prior page “Downloading MIB files” for
details.)
Refer to the USF-212AS/USF-105AS Operation Manual for details on SNMP settings.
GET List
Object
group
Item Name
Object name in MIB file
Value
OID
Type
TRAP
Function
OID: 1.3.6.1.4.1.20175.1.339.1.
Unit
Status
Product Name
usf105Dda12gProductName
USF-105DDA-12G
1.0 OCTET STRING
Product Code
usf105Dda12gProductCode
1023849
2.0 INTEGER
Serial Number
usf105Dda12gSerialNumber
1756****
3.0 INTEGER
Soft Version
usf105Dda12gVersion
**.**
4.0 OCTET STRING
Slot Number
usf105Dda12gSlotNumber
1-12
5.0 INTEGER
CPU Temperature
usf105Dda12gCpuTemperature ** degree Celsius
6.0 INTEGER
Input Video Status
usf105Dda12gInputStatus
-1:cannotDetect
0: not Detected
1: detected
7.0 INTEGER
Input SDI Bit Rate
usf105Dda12gSdiRate
-1:cannotDetect
0: not Detected
1: sdi SD
2: sdi HD
3: sdi 3G
4: sdi 6G
5: sdi 12G
8.0 INTEGER
Reclock Bypass Setting usf105Dda12gReclockBypass
0:reclocking
1:reclock Bypass
9.0 INTEGER
* No item can be set from SNMP.
TRAP List
Object
Group
Item Name
Object name in MIB file
OID
Reference object
Type
OID : 1.3.6.1.4.1.20175.1.339.0.
TRAP
SDI Input
usf105Dda12gInputStatusChanged
1.0
usf105Dda12gSlotNumber
INTEGER
usf105Dda12gInputStatus
INTEGER
* When video signal from internal bus of USF-212AS/USF-105AS is distributed, SDI Input trap is not sent out.