6. Web GUI
Status parameters of USF-1053DDA can be displayed on the Web display if the module is installed in a
USF frame. SNMP monitoring is also available. Refer to the USF frame operation manual for details on
displaying the Web GUI window.
NOTE
USF-1053DDA does not support simultaneous Web GUI access from multiple PCs. To
simultaneously monitor a USF-1053DDA from multiple PCs, use the SNMP function.
6-1. Web Display Information
Start the Web GUI and click on a USF-1053DDA from the installed slot number to open the window
as shown below.
Module Information
Item
Description
Slot
Slot no. of the USF frame in which USF-1053DDA is installed.
S/N
Serial Number of USF-1053DDA.
MAC Address
MAC address of USF-1053DDA.
Version
Software version of USF-1053DDA.
IP Address
IP address of USF-1053DDA.
CPU Temperature
Temperature of the CPU on the USF-1053DDA.
Video Input
Displays video input status.
Detected: Normal video input.
Not Detected: No video input, or input level is low.
When Input Source is set other than Rear In, input signal cannot be
detected. “------“ is displayed.
Input Status Trap
Sets the SNMP trap setting when monitoring USF-1053DDA via SNMP
manger;
Enable: Sends input status traps
Disable: Sends no traps.
When Input Source is set other than Rear In, input signal cannot be
detected so no trap is sent although Enable is selected.
Input Signal
(SD/HD/3G)
Displays the bit rate of SDI input;
SD (270Mbit/sec), HD (1.5Gbit/sec) or 3G (3.0Gbit/sec).
No Signal: No input signal.
When Input Source is set other than Rear In, input signal bit rate cannot
be detected. “------“ is displayed.
Mode
Displays the re-clock function mode.