USF-1053DDA
Digital Distribution Amplifier
2
nd
Edition
– Rev. 3
OPERATION
MANUAL
Страница 1: ...USF 1053DDA Digital Distribution Amplifier 2nd Edition Rev 3 OPERATION MANUAL ...
Страница 2: ...ircuitry exposed could result in electric shock fire hazards or a unit malfunction Potential Hazards Caution If abnormal odors or noises are noticed coming from the unit immediately turn the power off and disconnect the power cord to avoid potentially hazardous conditions If problems similar to the above occur contact an authorized service representative before attempting to operate the unit again...
Страница 3: ...cking list below Check to ensure no damage has occurred during shipment If damage has occurred or items are missing inform your supplier immediately USF 1053DDA ITEM QTY REMARKS USF 1053DDA 1 set USF 1053DDA Front Module USF 1053DDA Rear Module DVD ROM 1 Operation Manual PDF Screw for Rear Module Installation 2 This product can be installed into the following frames USF 212 USF 212S AS USF 105S AS...
Страница 4: ...ettings via Web GUI 11 5 USF 1053DDA I O via USF 105S AS Internal Bus 12 5 1 Slot 1 to Slot 2 12 5 1 1 Input Settings via DIP Switch 12 5 1 2 Input Settings via Web GUI 12 5 2 Slot 2 to Slot 1 13 5 2 1 Input Settings via DIP Switch 13 5 2 2 Input Settings via Web GUI 13 5 3 Slot 3 to Slot 4 13 5 3 1 Input Settings via DIP Switch 14 5 3 2 Input Settings via Web GUI 14 5 4 Slot 4 to Slot 3 14 5 4 1 ...
Страница 5: ... up to 5 outputs from 1 input 1 2 Features Installs into USF frames 1 input 5 distribution outputs Supports SDI 3Gbps 1 5Gbps and 270Mbps Automatic 3G HD SD SDI equalizer and re clock functions Detection of input signal and identification of 3Gbps 1 5Gbps 270Mbps is possible Supports DVB ASI 270Mbps signal 1 input 10 distribution outputs available with two USF 1053DDA modules Limitation on install...
Страница 6: ...tor Used to upgrade USF 1053DDA software Do not connect USB devices 1 When video signals routed from USF frame internal bus are distributed video signal bit rate detection is not available All the LEDs 270Mb s 1 5Gb s and 3 0Gb s are turned off Refer to Sec 4 USF 1053DDA I O via USF 212S AS Internal Bus for switching the video signal source 2 2 Rear Panel Name Description SDI IN SDI signal input A...
Страница 7: ...rame internal bus OFF OFF ON OFF Distributes Slot 3 input Via frame internal bus OFF OFF OFF ON Distributes Slot 4 input Via frame internal bus 2 ON OFF OFF OFF Distributes Slot 2 input Rear input OFF ON OFF OFF Distributes Slot 1 input Via frame internal bus OFF OFF ON OFF Distributes Slot 3 input Via frame internal bus OFF OFF OFF ON Distributes Slot 4 input Via frame internal bus 3 ON OFF OFF O...
Страница 8: ...s Slot 10 input Via frame internal bus OFF OFF ON OFF Distributes Slot 11 input Via frame internal bus OFF OFF OFF ON Distributes Slot 12 input Via frame internal bus 10 ON OFF OFF OFF Distributes Slot 10 input Rear input OFF ON OFF OFF Distributes Slot 9 input Via frame internal bus OFF OFF ON OFF Distributes Slot 11 input Via frame internal bus OFF OFF OFF ON Distributes Slot 12 input Via frame ...
Страница 9: ...f outputs can be increased up to 10 by installing two USF 1053DDA modules into a USF frame and using internal bus lines Install module pairs according to the figure shown above e g into Slot 1 and Slot 2 See Sec 4 1 Distributing another USF 1053DDA module input 1 x 10 USF 212S AS Frame Rear Panel Distributing another type module input A USF 1053DDA module can be paired with another type of USF mod...
Страница 10: ...53DDA SW1 SW2 SW3 SW4 Uses the rear panel input Slot 1 ON OFF OFF OFF USF 1053DDA SW1 SW2 SW3 SW4 Uses the Slot 1 input Slot 2 OFF ON OFF OFF See Sec 3 DIP Switch Settings for other USF 1053 module pair settings 4 1 2 Input Settings via Web GUI 1 Install two USF 1053DDA modules into Slots 1 and 2 2 Start the Web GUI and set as follows Set Slot 1 Input Source to Rear In Set Slot 2 Input Source to S...
Страница 11: ...F OFF ON 2 Install a USF 1043FS into Slot 4 of the USF frame 3 Input a video signal into SDI IN1 of the USF 1043FS in Slot 4 4 2 2 Input Settings via Web GUI 1 Install a USF 1053DDA into Slot 1 and USF 1043FS into Slot 4 2 Start the Web GUI and set as follows USF 1053DDA Set Slot 4 as the Slot 1 Input Source USF 1043FS Go to VIDEO Tab Video System System Settings and set Primary Source as SDI 1 3 ...
Страница 12: ...ge module settings using dip switches on the USF 1053DDA front panel or in the Web GUI page 5 1 Slot 1 to Slot 2 5 1 1 Input Settings via DIP Switch Set the front panel DIP switches on USF 1053DDA modules to those shown in the tables below and install them into Slot 1 and Slot 2 on the USF frame USF 1053DDA SW1 SW2 SW3 SW4 Uses the rear panel input Slot 1 ON OFF OFF OFF USF 1053DDA SW1 SW2 SW3 SW4...
Страница 13: ...ar panel input Slot 2 ON OFF OFF OFF 5 2 2 Input Settings via Web GUI 1 Install two USF 1053DDA modules into Slots 1 and 2 2 Start the 1053DDA Web GUI and set as follows Set Slot 1 Input Source to Slot 2 Set Slot 2 Input Source to Rear In 5 3 Slot 3 to Slot 4 3G HD SD SDI IN USF 1043FS 1 2 1 2 3 4 3G HD SD SDI OUT SDI IN 1 2 3 4 5 SDI OUT USF 1053DDA Slot 3 USF 1053DDA Slot 4 USF 1053DDA 3G HD SD ...
Страница 14: ...t 4 Input Source to Slot 3 5 4 Slot 4 to Slot 3 5 4 1 Input Settings via DIP Switch USF 1053DDA SW1 SW2 SW3 SW4 Uses the Slot 4 input Slot 3 OFF OFF OFF ON USF 1053DDA SW1 SW2 SW3 SW4 Uses the rear panel input Slot 4 ON OFF OFF OFF 5 4 2 Input Settings via Web GUI 1 Install two USF 1053DDA modules into Slots 3 and 4 2 Start the 1053DDA Web GUI and set as follows Set Slot 3 Input Source to Slot 4 S...
Страница 15: ...ss of USF 1053DDA Version Software version of USF 1053DDA IP Address IP address of USF 1053DDA CPU Temperature Temperature of the CPU on the USF 1053DDA Video Input Displays video input status Detected Normal video input Not Detected No video input or input level is low When Input Source is set other than Rear In input signal cannot be detected is displayed Input Status Trap Sets the SNMP trap set...
Страница 16: ...ber s set by Table 1 Input Signal Switch Settings are shown grayed out here if any of SW1 to SW4 switch es is are On Downloading MIB Files 1 Click to download the MIB Management Information Base for your SNMP manager 2 Select Save S from the opened dialog box 3 FORA USF1053DDA MIB zip File is downloaded 4 Unzip the file and load it into your SNMP manager ...
Страница 17: ... Facility Sets syslog logging facilities in Local 0 through Local 7 Header message Sets syslog header messages up to a maximum of 63 alphanumeric characters Factory setting USF 1053DDA Input video detect Sets detection messages for video input into USF 1053DDA maximum of 63 alphanumeric characters Sets priority in 9 steps Factory setting Notice Input video loss Sets detection messages for input vi...
Страница 18: ... usf1053DdaSerialNumber 1595 3 INTEGER Soft Version usf1053DdaVersion 4 OCTET STRING Slot Number usf1053DdaSlotNumber 1 12 5 INTEGER CPU Temperature usf1053DdaCpuTemperature degree Celsius 6 INTEGER Input Video Status usf1053DdaInputStatus 1 cannotDetect 0 not Detected 1 detected 7 INTEGER Input SDI Bit Rate usf1053DdaSdiRate 1 cannotDetect 0 not Detected 1 sdi SD 2 sdi HD 3 sdi 3G 8 INTEGER Reclo...
Страница 19: ...able HD SDI Max 100m Using 5C FB equivalent cable SD SDI Max 200m Using 5C 2V equivalent cable SNMP SNMP Monitoring available via USF frame SNMP version v2C Temperature 0ºC to 40 ºC Humidity 30 to 90 no condensation Power 12V DC Supplied by USF frame Power Consumption 3VA 3W Dimensions Front Module 106 W x 356 D mm Rear Module 114 W x 20 2 H mm Weight 220 g Required Slot 1 Slot 8 2 External Dimens...