![FOR-A MV-1200 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/for-a/mv-1200/mv-1200_installation-manual_2316700013.webp)
13
5. Install the internal wiring.
a. Fix the rear connector with the connector screws and the D-sub plate tie.
b. Connect the blue and white cables with the POWER2 switch on the front.
c.
Fix the internal wirings to the cable fixing bracket with cable ties.
Detach the cable ties fixing the POWER1 cables, join the MV-12PS cables and fix them
altogether again with cable ties.
d. Connect the wiring to the main card connector (CN21) and fix the wirings with the cable
fixing bracket. Fix the bracket with screws (M3x6).
6. Paste the power rating label.
Apply the label to the bottom panel of the upper side of the main unit label.
7. The installation of a redundant power supply is complete. Put the duct, cards, and the center
support removed in Steps 2. and 3. back, then put the top panel back in reverse procedure 1.
Main Unit Label
MV-12PS Power
Rating Label
b
c
d
c
c
c
c
Содержание MV-1200
Страница 16: ......