12
2-3. Installation of Redundant Power Supply MV-12PS
Installing an MV-12PS unit is explained in this section.
1. Same procedure as that of MV-12SDI / 12PCI / 12IF.
2. Remove the center support.
a. The center support is fastened by two screws (M3x6 Flat Head) on both ends.
3. When an optional card is already installed in the OUTPUT SLOT, you need to uninstall the
duct.
a. Uninstall the optional cards in the INPUT SLOT B and the IF SLOT.
Detach the two pan screws on the rear panel and two SEMS screws on the card in the
unit, then pull up the card vertically, to not damage the connectors.
b. Pull up the fan side of the duct and take out the duct from the unit taking care not to
break the protruding part of the duct.
4. Install the cable fixing bracket.
a. Align the location and fix the bracket with 4 screws (M3x6 Binding)
Cable Fixing
Bracket
D-sub
plate nut