[Circuitry Access] 

 
 
 
 

Do not

 remove covers, panels, casing, or access circuitry with power applied to the 

unit! Turn power off and disconnect power cord prior to removal. Internal servicing / 
adjustment of unit should only be performed by qualified personnel. 

 
 
 
 

Do not

 touch any parts / circuitry with a high heat factor. 

Capacitors can retain enough electric charge to cause mild to serious shock, even 
after power is disconnected. Capacitors associated with the power supply are 
especially hazardous. Avoid contact with any capacitors. 

 
 
 
 

Unit 

should not

 be operated or stored with cover, panels, and / or casing removed. 

Operating unit with circuitry exposed could result in electric shock / fire hazards or 
unit malfunction. 

[Potential Hazards] 

 
 
 
 

If abnormal smells or noises are noticed coming from the unit, turn power off 
immediately and disconnect power cord to avoid potentially hazardous conditions. If 
problems similar to above occur, contact authorized service representative 

before

 

attempting to again operate unit. 

[Consumables] 

 
 
 
 

The consumables used in unit must be replaced periodically. For further details on 
which parts are consumables and when they should be replaced, refer to the 
specifications at the end of the Operation Manual. Since the service life of the 
consumables varies greatly depending on the environment in which they are used, 
they should be replaced at an early date. For details on replacing the consumables, 
contact your dealer. 

[Rubber Feet] 

 
 
 
 

If this product has come with rubber feet attached by screws, do not insert the 
screws again without rubber feet after removing the rubber feet and screws. It may 
cause damage to the internal circuits or components of the unit. To install the rubber 
feet again to the unit, do not use other than the supplied rubber feet and screws. 

 

 

 

Caution 

Caution 

Hazard 

 

Stop 

Caution 

Содержание ADA+205A

Страница 1: ...ADA 205A Audio Distribution Amplifier 2nd Edition Rev 2 OPERATION MANUAL ...

Страница 2: ......

Страница 3: ...Ensure power cord is firmly plugged into AC outlet Operation Do not operate unit in hazardous or potentially explosive atmospheres Doing so could result in fire explosion or other dangerous results Do not allow liquids metal pieces or other foreign materials to enter the unit Doing so could result in fire other hazards or unit malfunction If foreign material does enter the unit turn power off and ...

Страница 4: ...diately and disconnect power cord to avoid potentially hazardous conditions If problems similar to above occur contact authorized service representative before attempting to again operate unit Consumables The consumables used in unit must be replaced periodically For further details on which parts are consumables and when they should be replaced refer to the specifications at the end of the Operat...

Страница 5: ...on Avoid using the ADA 205A in areas having high humidity high temperature or excessive dust Adequate ventilation is also required for optimum performance As a result of this consideration ensure no other equipment is located or installed closer than 5cm to any unit Desk or Tabletop Use Unit baseplate is fitted at the factory with rubber feet to allow immediate usage as a desk or tabletop unit Rac...

Страница 6: ...QTY REMARKS ADA 205A 1 Select the voltage range between 200 V or 100 V AC before purchasing AC Cord 1 Rack Mount Brackets 1 pr EIA standard type Operation Manual 1 Check Check to ensure no damage has occurred during shipment If damage has occurred or items are missing inform your supplier immediately IMPORTANT To change the voltage range from 200 V to 100 V or vice versa after purchasing products ...

Страница 7: ...1 1 3 About This Manual 1 2 Panel Descriptions 2 2 1 Front Panel 2 2 2 Rear Panel 3 3 Setup and Connection 4 3 1 Stereo Audio Input 4 3 2 Monaural Audio Input 5 3 3 XLR Connector Pin Assignment 6 4 Specifications and Dimensions 7 4 1 Unit Specifications 7 5 External Dimensions 8 ...

Страница 8: ......

Страница 9: ...to be of continuing service to you 1 2 About the ADA 205A The ADA 205A is a high performance balanced audio distribution amplifier capable of producing up to five stereo outputs from one stereo input and up to ten monaural outputs from one monaural input Features Front panel audio level control Convenient audio output level indicator located on front panel Compact and convenient EIA 1 RU size 1 3 ...

Страница 10: ... operation or output 6 7 8 9 10 audio level during monaural operation L CH LEVEL control Used to adjust either left channel audio gain during stereo operation or output 6 7 8 9 10 audio gain during monaural operation R CH LEVEL indicator Used to show either right channel audio level during stereo operation or output 1 2 3 4 5 audio level during monaural operation R CH LEVEL control Used to adjust ...

Страница 11: ... outputs from connector and 5 left channel stereo outputs form connector L INPUT Used to input left channel stereo audio signal when MODE switch is set to STEREO DO NOT connect this input when the MODE switch is set to MONO L OUTPUT Used to output audio signals distributed from input connector or above Outputs either 5 left channel stereo signals or 5 monaural signals depending on MODE switch sett...

Страница 12: ...PUT 1 2 3 4 5 and L OUTPUT 1 2 3 4 5 Connect the output stereo audio signals to other audio equipment 4 After all input and output connections are complete turn unit power ON 5 Adjust overall output levels using the L CH LEVEL and R CH LEVEL gain controls on the front panel Factory gain setting is 0dB Connection Example R INPUT MONO L OUTPUT 2 3 4 1 5 1 2 3 4 5 R OUTPUT L INPUT MONO 10 OUT STEREO ...

Страница 13: ... R OUTPUT 1 2 3 4 5 and L OUTPUT 6 7 8 9 10 Connect the output monaural audio signals to other audio equipment 4 After all input and output connections are complete turn unit power ON 5 Adjust overall output levels using the L CH LEVEL and R CH LEVEL gain controls on the front panel Factory gain setting is 0dB Connection Example CD LINE OUT LINE IN CASSETTE AUX IN AUDIO AMP R INPUT MONO L OUTPUT 2...

Страница 14: ... Pin Assignment Connector appearance and pin assignments are as follows Input connector XLR 3 pin female Pin No Signal 2 HOT 3 COLD 1 SHIELD Output connector XLR 3 pin male Pin No Signal 2 HOT 3 COLD 1 SHIELD 2 1 3 3 1 2 ...

Страница 15: ...sponse 20 Hz to 20 kHz 0 5 dB 1 kHz 0 dB base Distortion Less than 0 02 at 1 kHz 0 dB input S N Ratio Better than 75 dB at 1 kHz 0 dB input Temperature 0ºC to 40ºC Humidity 30 to 90 no condensation Power 100 V AC to 117 V AC or 220 V AC to 240 V AC 10 50 60 Hz 2 Consumption 12 VA 10 W at 100 VAC 11 VA 9 W at 220 V AC Dimensions 430 W x 44 H x 105 D mm Weight 2 kg 1 0dB 0 775V rms 2 To change the v...

Страница 16: ...VEL R CH LEVEL LEVEL OUTPUT POWER ADA 205A OFF ON 2x2 6 4x12 AUDIO DISTRIBUTION AMPLIFIER 480 462 390 20 44 32 6 6 8 20 Ø15 105 t2 430 79 12 14 R INPUT MONO L OUTPUT 2 3 4 1 5 1 2 3 4 5 R OUTPUT L INPUT MONO 10 OUT STEREO 6 7 8 9 10 0 3A MODE ON OFF R L INPUT 600 ...

Страница 17: ...en the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the in...

Страница 18: ...treet West Toronto Ontario M5V 2A2 Canada Phone 1 416 977 0343 Fax 1 416 977 0657 FOR A Latin America the Caribbean 5200 Blue Lagoon Drive Suite 760 Miami FL 33126 USA Phone 1 305 931 1700 Fax 1 305 264 7890 FOR A UK Limited UNIT C71 Barwell Business Park Leatherhead Road Chessington Surrey KT9 2NY UK Phone 44 0 20 8391 7979 Fax 44 0 20 8391 7978 FOR A Italia S r l Via Volturno 37 20047 Brugherio ...