: with this parameter you delay the boiler 

ignition to allow the zone valves to open. 

At the end of a heating 

request, it is the zone valve that closes late to ensure correct  post-circulation to the boiler pump.

The installer is asked to check the opening time in the characte

-

ristics of the valve and to set the Heating delay to the same  value [do not set below 30 seconds].

Содержание SPOT SMART THERMOSTAT

Страница 1: ...SPOT SMART THERMOSTAT INSTALLATION USE OFF EN Translation of the original instructions in Italian IST 03 C 1349 01...

Страница 2: ...rmitted All installation or maintenance operations must be carried out by qualified personnel The manufacturer cannot be held responsible for any damage to persons animals and or property caused by im...

Страница 3: ...e under supervision or have been instructed in the use of the ap pliance Children may not play with the appliance and or clean the appliance unless they have been properly instructed beforehand WARNIN...

Страница 4: ...3 Battery duration approx 2 years Fastening screws and plugs on bracket with integrated level GATEWAY RADIO RELAY CHARACTERISTICS Power supply 230Vac 10 15 Frequency 50 60Hz Relay dry contact gateway...

Страница 5: ...on off 4 heating request in progress 4 DHW request in progress 5 technical support enabling 5 battery 100 5 battery 75 5 battery 50 KEY 5 battery 25 5 low battery 6 progr thermostat in manual mode 6...

Страница 6: ...n gestures turn press press for three seconds wait for five seconds Set temperature 21 0 Set programmable thermostat function copy whole day paste whole day exit day of the week click to change day of...

Страница 7: ...How to select and set the time How to select and set the temperature...

Страница 8: ...perating mode Programmable thermostat settings It is possible to set 4 time slots per each day with free temperature for each time slot Setting of the tempera ture in the times outside the time slots...

Страница 9: ...CK Date and time setting Language set up Boiler thermore gulation setting Domestic hot water settings Area relay delay setting Display of Mac address Bluetooth signal quality Connection status Battery...

Страница 10: ...Operating mode MODE BACK WINTER OFF SUMMER WINTER OFF SUMMER WINTER OFF SUMMER WINTER OFF SUMMER OFF...

Страница 11: ...d to produce both hot water for heating and domestic hot water SUMMER the boiler is enabled to produce domestic hot water only Heating is disabled OFF each boiler operation request is disabled Antifre...

Страница 12: ...CH temperature setting HEATING WATER MAX MIN 70 C 30 C 11 24 THERMOSTAT 11 24 BACK BACK HEATING WATER MAX MIN 70 C 30 C HEATING WATER MAX MIN 70 C 30 C HEATING WATER...

Страница 13: ...room temp external temp room external MAX is the maximum temperature of the heating water that the boiler will provide in modulating operation regulation type room temp external temp room external MAX...

Страница 14: ...DHW temperature setting BACK HEATING WATER DOMESTIC HOT WATER DOMESTIC HOT WATER 49 C 49 C DOMESTIC HOT WATER 11 24 THERMOSTAT...

Страница 15: ...DOMESTIC HOT WATER the boiler will produce domestic hot water at the temperature set with this parameter...

Страница 16: ...FERENTIAL ON OFF 0 1 0 CORR 0 0 5 0 11 24 THERMOSTAT HEATING WATER DOMESTIC HOT WATER DIFFERENTIAL DIFFERENTIAL ON value to be subtracted from the ambient set point that determines a heating request e...

Страница 17: ...under which an antifre eze request is triggered regardless of the operating mode CORR ambient probe correction Value to add subtract to offset any error DIFFERENTIAL OFF value to be added to the ambie...

Страница 18: ...ION TYPE ROOM TEMP EXTERNAL TEMP ROOM EXTERNAL ON OFF ROOM the temperature of the hot water for heating varies within MAX MIN values depending on the ambient tem perature This guarantees lower gas con...

Страница 19: ...AL ON OFF BACK ROOM EXTERNAL the temperature of the hot water for hea ting varies within MAX MIN values depending on the external temperature and the ambient temperature EXTERNAL the temperature of th...

Страница 20: ...g the regulation curve of hot water for heating to be made by the installer 11 24 THERMOSTAT DIFFERENTIAL REGULATION TYPE CURVE PROPORTIONAL FACTOR 11 24 BACK HEATING WATER DOMESTIC HOT WATER HEATING...

Страница 21: ...3 The higher the value the greater the influence of the external temperature Values between 0 1 and 0 9 are values for floor systems Values between 1 and 3 are values for radiator systems Usually it...

Страница 22: ...Proportional factor setting by the installer HEATING WATER DOMESTIC HOT WATER DIFFERENTIAL REGULATION TYPE CURVE PROPORTIONAL FACTOR HEATING DELAY 11 24 BACK 11 24 THERMOSTAT...

Страница 23: ...PORTIONAL FACTOR this parameter affects the relation between external ambient temperature and heating water tem perature The range goes from 0 to 20 The higher the value the greater the influence of t...

Страница 24: ...Heating delay setting by the installer 11 24 THERMOSTAT HEATING WATER DOMESTIC HOT WATER DIFFERENTIAL REGULATION TYPE CURVE PROPORTIONAL FACTOR HEATING DELAY 11 24 BACK...

Страница 25: ...allow the zone valves to open At the end of a heating request it is the zone valve that closes late to ensure correct post circulation to the boiler pump The installer is asked to check the opening ti...

Страница 26: ...ough the Webapp accessible from the Fondital website Technical support enabling From the settings page the user can enable or disable the remote control of the boiler and heating system by the Fondita...

Страница 27: ...on for the first time re member to set the correct date and time WARNING the batteries can be replaced only by the user The manufactu rer cannot be held responsible for any damage to persons animals a...

Страница 28: ...GATEWAY INSTRUCTIONS Gateway description Front Rst button reset programming BLE LED bluetooth blue WiFi LED blue not used Cloud LED blue Power LED green...

Страница 29: ...US connector to be connected to the boiler Non polarised connection red live power supply 90 230 Vac 50 60 Hz black neutral power supply 90 230 Vac 50 60 Hz yellow green dry contact for zone valve ena...

Страница 30: ...pply of the gateway so that it is in parallel with the boiler power sup ply downstream the same bipolar switch IT IS IMPORTANT THAT GATEWAY AND BOILER TURN ON AT THE SAME TIME Connect the dry open con...

Страница 31: ...y Gateway status Cloud LED it signals the connection to the home Wifi network and to the Spot cloud Off it means that the Gateway is not connected to any WiFi network or no account has been connected...

Страница 32: ...Step 2 Press and hold the Rst button until you see the BLE LED switching from 5 fast blinks per se cond to one blink per second Press and hold on the Spot thermostat from the main page for three secon...

Страница 33: ...MYSPOT app from Google play store or Apple app store Open the App first create your account by following the App s instruc tions and then register the gateway to your home Wi Fi network Step 1 Step 2...

Страница 34: ...hen select Jotto_Config_AP choose the WiFi network to which you want to connect the Gateway and type the correct password After connecting to the cloud the message indicating the presence of a new Spo...

Страница 35: ......

Страница 36: ...ls of the WiFi network you want to connect to and be sure that this network has an internet connection Step 1 Step 2 5 times Power up the Gateway wait for a couple of mi nutes Press the Rst button 5 t...

Страница 37: ...then change on access point detail Then select Jotto_Con fig_AP choose the WiFi network to which you want to connect the Gateway and type the correct password After connecting to the cloud the app wi...

Страница 38: ......

Страница 39: ...the Rst button until you see the BLE LED switching from 5 fast blinks per se cond to one blink per second Click on the Rst button the Cloud LED will blink once per second it is possible to pair a WiFi...

Страница 40: ...he third Spot thermostat follow steps 3 and 4 defined in the previous chapter Modify the Gateway Wi Fi network Press the Rst button again the Cloud LED will blink fast three times every second you are...

Страница 41: ...Connect the relay as shown in the figure below Neutral output Phase 220VAC Neutral Connect to 230Vac zone solenoid valve Fondital zone kit Maximum current 10A at 230Vac The relay is modified according...

Страница 42: ...3 Go to WiFi and select the net work Spot_RL_xxxx exit and open the browser and type the address 192 168 4 1 The following relay page will open click on Configure wifi The page shows the available WiF...

Страница 43: ...e lay will stop blinking and will become steady if this is not the case repeat the procedure from the beginning Now the relay is ready to be paired with the Ga teway When you reach points 4 and 6 of t...

Страница 44: ...boiler operating mode WINTER SUMMER OFF and adjust the domestic hot water temperature Each thermostat displays the current boiler status heating or domestic hot water request if the boiler burner is...

Страница 45: ...RELE WIFI 230Vac V2 230Vac 230Vac 230Vac V1 V3 N L 230Vac 50Hz GATEWAY BUS 230Vac ROUTER RELE WIFI BOILER...

Страница 46: ...2 TSM2 VM2 PR2 SEXT 230Vac GATEWAY BUS N L 230Vac 50Hz POWER POWER 230Vac ROUTER RELE WIFI BOILER ZONE 1 THERMOSTAT Z1 ZONE 2 ZONE 2 board THERMOSTAT Z2 ZONE 3 ZONE 3 board THERMOSTAT Z3 ZONE 1 RELAY...

Страница 47: ...3 RELAY THERMOSTAT ZONE 3 BOARD BOILER ZONE1 AND ZONE3 THERMOSTATS it is mandatory to set the curves 0 BOILER Set P60 2 no of present zones Set P61 0 Set P10 high temperature curve Set zone 1 tempera...

Страница 48: ...39 0365 878 31 Fax 39 0365 878 304 e mail info fondital it www fondital com The manufacturer reserves the right to modify his her products as deemed necessary without altering the basic characteristi...

Отзывы: