: with this parameter you delay the boiler
ignition to allow the zone valves to open.
At the end of a heating
request, it is the zone valve that closes late to ensure correct post-circulation to the boiler pump.
The installer is asked to check the opening time in the characte
-
ristics of the valve and to set the Heating delay to the same value [do not set below 30 seconds].