: this parameter affects the relation between external
temperature and heating water temperature.
The range goes
from 0 to 3.
The higher the value, the greater the influence
of the external temperature. V
alues between 0.1 and 0.9 are
values for floor systems. V
alues between 1 and 3 are values
for radiator systems. Usually
, it is possible to set curves=0.6 for
floor systems and curves=1.5 for radiator systems.
Value 0 must be set in particular installations (see Gateway manual).