23
AST 14 C 259/00
4.4 TSP PARAMETERS
PCBs house a memory with a series of parameters (called TSP parameters) to be
accessed for displaying purposes only, or to be edited for boiler perfect setting based on
the system used. These parameters can be directly accessed from user's interface, or
through the remote control.
TSP parameter displaying
Press “info” several times to scroll the list of parameter values (see paragraph “TSP
parameter list”).
Parameters are displayed by alternating every three seconds the parameter screen (ex.
P09) and the corresponding value (ex. 3):
To quit the displaying function, simply press “reset”. Display will anyway go back to the
starting screen 30 seconds after button has been pressed.
TSP parameter editing
If buttons “reset” and “- heating” are pressed together for three seconds, you will access
the parameter programming mode. Press “+/- heating” to select the desired parameter
(see paragraph "TSP parameter list")
, and parameter screen (ex. P09) will be alternatively
displayed - every three seconds - with the corresponding value (ex. 3):
Press “OK” to confirm that parameter value has to be edited; the adjustable wrench
symbol indicates that parameter value can be edited using keys “+/- heating”: