________________________________________________________________________________
19
AST 14 C 259/00
3.6 GAS VALVE
Boiler is homologated to operate with the following valve models:
SIEMENS VGU 56
SIT 845
GAS OUT
GAS IN
Gas inlet
pressure
t
Gas output
pressure
t
Min. pressure
adjuster screw
B
Max. pressure
adjuster screw
C
GAS OUT
GAS IN
Pressure
measurement
Min. pressure
adjuster screw
B
Max. pressure
adjuster screw
C
Pressure
measurement
i t