________________________________________________________________________________
11
AST 14 C 152/00
WARNING LIGHTS IN THE CASE OF MALFUNCTIONING OR SHUT- DOWN OF THE BOILER
1
2
3
4
5
6
7
8
Condizione
Green
Red
Red
Red
Red
Red
Red
Red
Flame detection s hut-down
X
OFF
OFF
OFF
ON L
OFF
OFF
OFF
Safet y t hermostat shut-down
X
OFF
ON L
OFF
OFF
OFF
OFF
OFF
Wat er press ure shut-down
X
OFF
OFF
OFF
OFF
ON L
OFF
OFF
Smoke t her most at./ press. s hut- down
X
OFF
OFF
ON L
OFF
OFF
OFF
OFF
Flow probe malfunction
X
ON L
OFF
OFF
OFF
OFF
OFF
ON L
DHW probe malf unction
X
ON L
OFF
OFF
OFF
OFF
OFF
OFF
Wat er tank probe malfunction
X
ON LA
OFF
OFF
OFF
OFF
OFF
ON LA
Gas modulat or malfunction
X
OFF
ON L
OFF
OFF
OFF
OFF
ON L
Remote c ontrol malfunc tion
X
OFF
OFF
ON L
OFF
OFF
OFF
ON L
Flow t emperature 90° or more
X
OFF
OFF
OFF
OFF
OFF
ON L
X
Wat er tank in heating phas e
X
X
X
X
X
X
X
ON
Power connection
ON
X
X
X
X
X
X
X
Key chart:
OFF
- Led off
ON
- Led on, fixed
ON L - Led on, flashing
ON LA - Led on, flashing alternately