5. ELECTRICAL CONNECTIONS
IMPORTANT
During installation, maintenance and cleaning, the appliance must be disconnected from the power supply.
The appliance must be connected to a 230 Vca power supply only. Respect colours as shown in the table.
Brown
Phase
Blue or grey
Neutral
Black
Pilot wire
Note:
The pilot wire is used in radiators sold in France.
If the pilot wire is not used, regulations require that it be isolated. Never connect it to the earth lead for any reason.
A multi-pole circuit breaker must be installed. The distance between the contacts must be at least 3 mm.
The appliance’s power circuit must be protected by a high sensitivity differential protection device.
The power cord must be connected to the power supply using a shunt box located 25 cm from the ground, without the use of an electrical plug.
Never insert metal objects into or attempt to piece the side of the radiator containing the regulation system (right side).
If the power cord is damaged, it must be replaced by a qualified electrician only.