General information for installers, service engineers and users

This INSTRUCTION MANUAL, 
which is an integral and indispen-
sable part of the product, must be 
handed over to the user by the 
installer and must be kept in a 
safe place for future reference. The 
manual must accompany the boiler 
should it be sold or moved. 

This boiler must be used for the 
purpose for which it has been 
designed. Any other use is con-
sidered incorrect and therefore 
dangerous.

The boiler must be installed in com-
pliance with applicable laws and 
standards and according to the 
manufacturer’s instructions given in 
this manual. Incorrect installation 
may cause injury or damage, for 
which the manufacturer cannot be 
held liable. 

Damage or injury caused by incorrect 
installation or use or failure to obser-
ve the manufacturer’s instructions 
shall relieve the Manufacturer of all 
liability whether under a contract 
or not. Before installing the boiler, 
check that the specification meets 
the requirements of the system in 
which it is to be installed.

Check that the boiler is intact and 
that it has not been damaged during 
transport and handling. Do not install 
equipment which is clearly damaged 
or faulty. 

Do not obstruct the air intake or heat 
dissipation grates. 

Only original accessories must be 
used for all boilers supplied with 
optionals or kits (including electri-
cal ones). All the packaging mate-
rials can be recycled and should be 
sent to specific waste management 
sites.
Keep the packaging out of the reach 
of children as it constitutes a serious 
hazard.
In the event of a malfunction, switch 
off the boiler immediately. Do not 
attempt to make any repairs and 
contact a qualified technician.
Original parts must be used for all 

repairs to the boiler. Failure to do 
this may jeopardize the safety of the 
boiler and create a serious hazard.

To guarantee efficiency and cor-
rect operation of the boiler, it is 
legally binding to service  the boi-
lers once a year according to the 
schedule indicated in the relevant 
section of this manual.

If the boiler is not used for a certain 
length of time, switch off the electri-
city and fuel supply. Place some 
calcium carbonate inside the com-
bustion chamber to absorb moisture. 
Should there be a risk of  freezing, 
add anti-freeze. It is not advisable to 
empty the system as this may result 
in damage. Use a specific anti-free-
ze for multi-metal heating systems.

IMPORTANT

If there is a smell of gas, when 
using a gas-fired boiler, always fol-
low these rules. 
- Do not operate any electrical 
switches or electrical appliances.
- Do not light any flames and do not 
smoke.
- Close the main gas tap. 
- Open all doors and windows wide.
- Contact a Service Centre, a quali-
fied installer or the gas supply com-
pany.
Never use a flame to detect a gas 
leak. 

WARNING
This boiler has been built for instal-
lation only in the country indicated 
on the rating plate. Installation in 
any other country may cause injury 
or damage.

Содержание ELBA DUAL 23

Страница 1: ...INSTALLATION USE AND MAINTENANCE ELBA DUAL GB IST 03 C 202 01...

Страница 2: ...hank you for choosing our boilers Please read these installation and maintenance instructions with care Please note that the boiler must only be installed repaired and serviced by qualified personnel...

Страница 3: ...All the packaging mate rials can be recycled and should be sent to specific waste management sites Keep the packaging out of the reach of children as it constitutes a serious hazard In the event of a...

Страница 4: ...Packaging page 10 3 2 2 Choosing where to install the boiler page 10 3 2 3 Installing the boiler page 10 3 2 4 Room ventilation page 10 3 2 5 Flue gas system page 10 3 2 6 Choosing and installing the...

Страница 5: ...s light is on it means the safety thermostat has cut in due to overheating and needs to be reset manually Burner light yellow E This light indicates that the burner is in operation Thermometer F The t...

Страница 6: ...t a quali fied technician or an authorised Service Centre 1 2 3 Shutdown due to overhea ting If red light D comes on due to overheating it means the safety thermostat has cut in due to a recurrent mal...

Страница 7: ...22 July 1993 and are fitted with all the safety features required by the applicable laws The main technical features of the boilers are listed below High efficiency cast iron heat exchanger with 3 sm...

Страница 8: ...285 4 FORI M8 110 150mm 65mm 57 486 5 mm mm mm 82 5 mm 235 mm 627 mm 225 mm 65mm 82 5 mm MODEL L Flow A Return B 23 400 1 1 4 1 33 525 1 1 4 1 43 625 1 1 4 1 53 700 1 1 4 1 63 800 1 1 4 1 73 900 1 1 4...

Страница 9: ...rate l h 680 950 1230 1520 1800 2150 Combustion chamber length mm 208 308 408 508 608 708 Flue gas temperature C 210 190 188 202 181 175 Flue gas flow rate Kg h 40 53 2 69 3 8 1 97 7 114 5 Working pr...

Страница 10: ...allet pic 3 Pass belts or cables underneath the boiler and around the legs lift it off the pallet and place it in position on the ground Attention when lifting the boiler from the pallet hold it to pr...

Страница 11: ...gs when the boi ler is running at a steady state 3 2 8 Connecting to the gas mains for boilers with gas bur ners The cross section of the gas sup ply pipe must be equal to or grea ter than that of the...

Страница 12: ...Gradually open the water inlet tap and check that the relief valves in the system if there are any are working properly Close the radiator air vents as soon as water starts to come out Check on the p...

Страница 13: ...Room thermostat connection Water pressure switch connection Electric feeding 3 5 2 General layout a light blue bl blue bk black br brown g grey gn green r red v purple y yellow ygn yellow green IG F...

Страница 14: ...L5 Overheating light L6 Burner stop light optional MT Programming clock motor optional indicated with TIMER on the PCB TM Programming clock contact optional indicated with TIMER on the PCB PA Water pr...

Страница 15: ...iler cold the boiler as a whole the burner this may also need to be reset according to the manu facturer s instructions see combu stion check boiler room ventilation grille flue gas side of the heat e...

Страница 16: ...Fax 39 0365 878 576 e mail info fondital it www fondital it The MANUFACTURER reserves the right to implement any necessary and or useful variation to products without modifying fundamental characteri...

Отзывы: