background image

11

0

2

4

6

8 10 12 14 16 18 20

TL

TH

6.6.  

Description of operating modes

6.6.1.  Programming mode

In this mode, the ambient temperature remains at the TH or TL level, depending on the times set by the user. 

0

4

8

12

16

20

24

Confirm the selection using the ‘mode’ key. 
This same process must be repeated for each day of the week (1-7). 

6.6.2.  Pilot Wire mode (for radiators installed in France only) 

This mode enables the user to control the radiator from a remote location.

1. Press the ‘mode’ key until the screen displays the icon 

2. Select the desired temperature using the + and - keys. The operating mode will be selected by the Pilot Wire control centre.

6.6.3.  Comfort mode 

This is the normal mode when the radiator is in use, keeping the ambient temperature at the programmed level.

1. Press the ‘mode’ key until the screen displays the icon 

2. Select the desired temperature using the + and - keys.

6.6.4.  Night-time mode 

When this operating mode is selected, the radiator will keep the ambient temperature at the programmed TL temperature. The desired TL 

temperature is programmed as follows: 

1. Press the ‘mode’ key until the screen displays the icon 

2. Select the desired TL temperature using the + and - keys.

6.6.5.  Anti-freeze mode 

When this mode is selected, the ambient temperature will not drop below 7ºC.

6.6.6.  Stand-by mode

The radiator is in stand-by mode.

Содержание Alcor FD

Страница 1: ...INSTALLATION AND MAINTENANCE MANUAL Alcor FDR Aluminium electric radiators with heat transfer fluid GB IST 03 F 042 01...

Страница 2: ...n location THE PACKAGE INCLUDES Aluminium radiator fitted with a thermostat with electronic regulation kit made up of three mounting brackets with wall plugs and instruction manual CONTENTS 1 CHARACTE...

Страница 3: ...at internally This fluid is made up of highly refined mineral oil with a high heat transmission coefficient characterized by high oxygenation resistance for durability and low viscosity The internal f...

Страница 4: ...e been given supervision or instruction concerning use of the appliance by a person responsibke for their safety Children should be supervised to ensure that they do not play with the appliance All wo...

Страница 5: ...with the appliance The mounting system consists of When mounting follow the steps illustrated below x2 x2 x2 x3 x1 x3 x3 1 2 Number of sections 3 350W 5 600W 6 800W 7 1000W 9 1200W 11 1500W 12 1800W...

Страница 6: ...n 6 can only be considered finished when the lower screw has been completely tightened and the radiator is firmly fixed to the wall with no possible movement The minimum distance between the radiator...

Страница 7: ...0 AREA 0 AREA 1 AREA 2 AREA 3 5 ELECTRICAL CONNECTIONS Important When installing or cleaning your Vantage Electric Radiator it must be disconnected from the power supply The Vantage Electric Radiator...

Страница 8: ...or has various operating modes as shown in the table on page 13 When the radiator is in clock mode the screen shows the time in the other modes it shows the programmed temperature A small icon indicat...

Страница 9: ...me Reduction mode The two temperature levels are also used when programming 0 2 4 6 8 10 12 14 16 18 20 TL TH TH is the desired ambient temperature during the time periods selected TL is the reduced d...

Страница 10: ...the TH temperature is desired Pressing the key activates the segment on the screen and therefore TH as well Pressing the key deactivates the segment and the programmed temperature will be equivalent t...

Страница 11: ...keys The operating mode will be selected by the Pilot Wire control centre 6 6 3 Comfort mode This is the normal mode when the radiator is in use keeping the ambient temperature at the programmed level...

Страница 12: ...y and weekly programming which sets the two temperature levels Comfort and Night time defined by the user for each time of day Pilot wire The temperature depends on the Pilot Wire control for radiator...

Страница 13: ...the temperature programmed The room does not get hot enough in Comfort mode LCD lit in the desired mode The radiator is not large enough for the size of the room Replace the radiator with one with gr...

Страница 14: ...gnetic compatibility DIRECTIVE 2002 96 CE of 27 January 2003 on waste from electrical and electronic equipment WEEE And in accordance with the following harmonized regulations EN 60335 1 safety of ele...

Страница 15: ...15...

Страница 16: ...65 878 31 Fax 39 0365 878 576 e mail info fondital it www fondital it The manufacturer reserves the right to modify the products as it deems necessary and useful without affecting their basic features...

Отзывы: