22
1.7. CONNECTION OF THE APPLIANCE
The firebox must be connected to the duct using one of the means described in DTU 24.2.2.All the
elements necessary to this connection are marketed by FONDIS S.A.
FIREBOX CONNECTION USING A FLEXIBLE STAINLESS STEEL DUCT
In the case of a connection of the firebox with a flexible stainless steel duct (with technical notice):
exclusively use the REDI FONDIS adaptative part to imperatively attach to the firebox nozzle.Ref.
= REDI…(+ vent diam. + flexible casing inside diam.).
Ex: REDI2320
PRINCIPLE OF CASING COMING DIRECTLY FROM THE INSERT
The casing is the introduction, inside the existing chimney flue, of an independent tube (see NFP
51-201 / DTU 24.1). In no case can it be considered as a defective duct repair, and neither to have
the effect of restoring its integrity and/or stability.
p a ssa ge
d 'a ir m in i 20
c m 2
p a ssa g e d 'a ir
m in i 5 cm 2